Cell Type
NOR
Density
128Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
11 200
Part Number:
M29W128GL70N6E
Manufacturer:
LATTICE
Quantity:
198
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
STM
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
M29W128GL70N6E
Quantity:
920
Company:
Part Number:
M29W128GL70N6E
Quantity:
900
5.2.2
Note:
5.3
Note:
1
2
Refer to
details on the block protection mechanism, and to
volatile protection mode command set.
Non-volatile protection bit lock bit
The non-volatile protection bit lock bit (NVPB lock bit) is a global volatile bit for all blocks.
When set (programmed to ‘0’), it prevents changing the state of the NVPBs. When cleared
(programmed to ‘1’), the NVPBs can be set and reset using the NVPB Program command
and Clear all NVPBs command, respectively.
There is only one NVPB lock bit per device.
Refer to
No software command unlocks this bit unless the device is in password protection mode; it
can be cleared only by taking the device through a hardware reset or a power-up.
The NVPB lock bit must be set (programmed to ‘0’) only after all NVPBs are configured to
the desired settings.
Password protection mode
The password protection mode provides an even higher level of security than the non-
volatile protection mode by requiring a 64-bit password for unlocking the device NVPB lock
bit.
In addition to this password requirement, the NVPB lock bit is set ‘0’ after power-up and
reset to maintain the device in password protection mode. Successful execution of the
Password Unlock command by entering the correct password clears the NVPB lock bit,
allowing for block NVPBs to be modified.
If the password provided is not correct, the NVPL lock bit remains locked and the state of
the NVPBs cannot be modified.
To place the device in password protection mode, the following steps are required:
1.
2.
Refer to
There is no means to verify the password after it is set. If the password is lost after setting
the password mode lock bit, there is no way to clear the NVPB lock bit.
Prior to entering the password protection mode, it is necessary to set a 64-bit password
and to verify it (see
verification is only allowed during the password programming operation
The password protection mode is then activated by programming the password
protection mode lock bit to ‘0’. This operation is not reversible and once the bit is
programmed it cannot be erased, the device permanently remains in password
protection mode, and the 64-bit password can neither be retrieved nor reprogrammed.
Moreover, all commands to the address where the password is stored, are disabled.
Refer to
details on the block protection scheme.
Table 19: Block protection status
Section 6.3.6
Section 6.3.4
Table 19: Block protection status
for a description of the NVPB lock bit command set.
for a description of the password protection mode command set.
Password protection mode command set on page
and
and
Figure 5: Software protection scheme
Section 6.3.5
Figure 5: Software protection scheme
for a description of the non-
42). Password
for
25/94
for

Related parts for M29W128GL70N6E