Specifications of M29W128GL70N6E

Cell Type
NOR
Density
128Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
11 200
Part Number:
M29W128GL70N6E
Manufacturer:
LATTICE
Quantity:
198
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
STM
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
M29W128GL70N6E
Quantity:
920
Company:
Part Number:
M29W128GL70N6E
Quantity:
900
6.2.2
All the addresses used in the write to buffer program operation must lie within the same
page.
To program the content of the write buffer, this command must be followed by a Write to
Buffer Program Confirm command.
If an address is written several times during a write to buffer program operation, the
address/data counter will be decremented at each data load operation and the data will be
programmed to the last word loaded into the buffer.
Invalid address combinations or failing to follow the correct sequence of bus write cycles will
abort the write to buffer program.
The status register bits DQ1, DQ5, DQ6, DQ7 can be used to monitor the device status
during a write to buffer program operation.
It is possible to detect program operation fails when changing programmed data from ‘0’ to
‘1’, that is when reprogramming data in a portion of memory already programmed.
See
suggested flowchart on using the Write to Buffer Program command.
Enhanced Buffered Program command
The Enhanced Buffered Program command, available only in x 16 mode, makes use of the
device’s 256-word write buffer to speed up programming. 256 words can be loaded into the
write buffer. Each write buffer has the same A22-A8 addresses. The Enhanced Buffered
Program command dramatically reduces system programming time compared to both the
standard non-buffered Program command and the Write to Buffer command.
When issuing an Enhanced Buffered Program command, the V
High, V
See
typical enhanced buffered program times in both cases.
Three successive steps are required to issue the Enhanced Buffered Program command:
To program the content of the write buffer, the Enhanced Buffered Program command must
be followed by an Enhanced Buffered Program Confirm command. The command ends with
an internal enhanced buffered program confirm cycle.
Note that address/data cycles must be loaded in an increasing address order (from
ADD[7:0]=00000000 to ADD[7:0]=11111111) and completely (all 256 words). Invalid address
combinations or failing to follow the correct sequence of bus write cycles will abort the
enhanced buffered program.
The status register bits DQ1, DQ5, DQ6, and DQ7 can be used to monitor the device status
during an enhanced buffered program operation.
An external supply (12 V) can be used to improve programming efficiency.
Appendix
Table 17: Program, erase times and program, erase endurance cycles
The Enhanced Buffered Program command starts with two unlock cycles
The third bus write cycle sets up the Enhanced Buffered Program command. The setup
code can be addressed to any location within the targeted block
The fourth bus write cycle loads the first address and data to be programmed. There a
total of 256 address and data loading cycles.
IH
, or raised to V
D,
Figure 30: Write to buffer program flowchart and
PPH
.
PP
/WP pin can be either held
pseudocode, for a
for details on
35/94