M29W128GL70N6E Micron Technology Inc, M29W128GL70N6E Datasheet - Page 30

no-image

M29W128GL70N6E

Manufacturer Part Number
M29W128GL70N6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W128GL70N6E

Cell Type
NOR
Density
128Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
11 200
Part Number:
M29W128GL70N6E
Manufacturer:
LATTICE
Quantity:
198
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
STM
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
M29W128GL70N6E
Quantity:
920
Company:
Part Number:
M29W128GL70N6E
Quantity:
900
6.1.7
6.1.8
6.1.9
30/94
If the erase suspend operation is aborted by performing a reset or powering down the
device, data integrity cannot be ensured, and it is recommended to erase again the blocks
suspended.
Erase Resume command
The Erase Resume command is used to restart the program/erase controller after an erase
suspend.
The device must be in read array mode before the Resume command will be accepted. An
erase can be suspended and resumed more than once.
Program Suspend command
The Program Suspend command allows the system to interrupt a program operation so that
data can be read from any block. When the Program Suspend command is issued during a
program operation, the device suspends the program operation within the program suspend
latency time (see
and updates the status register bits.
After the program operation has been suspended, the system can read array data from any
address. However, data read from program-suspended addresses is not valid.
The Program Suspend command may also be issued during a program operation while an
erase is suspended. In this case, data may be read from any addresses not in erase
suspend or program suspend. If a read is needed from the extended memory block area
(one-time program area), the user must use the proper command sequences to enter and
exit this region.
The system may also issue the Auto Select command sequence when the device is in the
program suspend mode. The system can read as many auto select codes as required.
When the device exits the auto select mode, the device reverts to the program suspend
mode, and is ready for another valid operation. See Auto Select command sequence for
more information.
If the program suspend operation is aborted by performing a reset or powering down the
device, data integrity cannot be ensured, and it is recommended to program again the
words or bytes aborted.
Program Resume command
After the Program Resume command is issued, the device reverts to programming. The
controller can determine the status of the program operation using the DQ7 or DQ6 status
bits, just as in the standard program operation. Refer to
program waveforms (8-bit mode)
waveforms (16-bit mode)
The system must issue a Program Resume command, to exit the program suspend mode
and to continue the programming operation.
Further issuing of the Resume command is ignored. Another Program Suspend command
can be written after the device has resumed programming.
Table 17: Program, erase times and program, erase endurance
for details.
and
Figure 18: Write enable controlled program
Figure 17: Write enable controlled
cycles)

Related parts for M29W128GL70N6E