M29W128GL70N6E Micron Technology Inc, M29W128GL70N6E Datasheet - Page 90

no-image

M29W128GL70N6E

Manufacturer Part Number
M29W128GL70N6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W128GL70N6E

Cell Type
NOR
Density
128Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
11 200
Part Number:
M29W128GL70N6E
Manufacturer:
LATTICE
Quantity:
198
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
STM
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
M29W128GL70N6E
Quantity:
920
Company:
Part Number:
M29W128GL70N6E
Quantity:
900
Appendix D
Figure 30. Write to buffer program flowchart and pseudocode
1. n+1 is the number of addresses to be programmed.
2. A write to buffer program abort and reset must be issued to return the device in read mode.
3. When the block address is specified, any address in the selected block address space is acceptable. However when
4. DQ7 must be checked since DQ5 and DQ7 may change simultaneously.
5. If this flowchart location is reached because DQ5=’1’, then the Write to Buffer Program command failed. If this flowchart
6. See
90/94
loading write buffer address with data, all addresses must fall within the selected write buffer page.
location is reached because DQ1=’1’, then the Write to Buffer Program command aborted. In both cases, the appropriate
reset command must be issued to return the device in read mode: a Reset command if the operation failed, a Write to
Buffer Program Abort and Reset command if the operation aborted.
Table 10
and
Table
11, for details on Write to Buffer Program command sequence.
Flowcharts
YES
NO
DQ1 = 1
NO
Write to Buffer Program
Confirm, block address
Check Status Register
Read Status Register
Program Address Pair
(DQ1, DQ5, DQ7) at
last loaded address
last loaded address
FAIL OR ABORT
Write Buffer Data,
(DQ5, DQ7) at
Write to Buffer
block address
block address
Write Next Data,
start address
DQ7 = Data
DQ7 = Data
Abort Write
command,
Write n
to Buffer
DQ5 = 1
X = X-1
X = 0
Start
YES
X=n
(4)
NO
NO
YES
NO
NO
(1)
,
(5)
YES
YES
(3)
YES
Program Aborted
Write to Buffer and
Write to a different
block address
Write to Buffer and Program command
END
First three cycles of the
(2)
AI08968b