AT90USB647 Atmel Corporation, AT90USB647 Datasheet - Page 296

no-image

AT90USB647

Manufacturer Part Number
AT90USB647
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT90USB647

Flash (kbytes)
64 Kbytes
Pin Count
64
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
48
Ext Interrupts
16
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
2
Twi (i2c)
1
Uart
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
4
Eeprom (bytes)
2048
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
4
Output Compare Channels
10
Input Capture Channels
1
Pwm Channels
9
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AT90USB647-16AE
Quantity:
8
Part Number:
AT90USB647-16AU
Manufacturer:
HITACHI
Quantity:
2 000
Part Number:
AT90USB647-AU
Manufacturer:
MURATA
Quantity:
1 000
Part Number:
AT90USB647-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT90USB647-AUR
Manufacturer:
Atmel
Quantity:
1 951
Part Number:
AT90USB647-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
23.14.1
23.15 Interrupt system
296
AT90USB64/128
CRC Error (isochronous only)
Each time the current bank is full, the RXIN and the FIFOCON bits are set. This triggers an inter-
rupt if the RXINE bit is set. The firmware can acknowledge the USB interrupt by clearing the
RXIN bit. The Firmware read the data and clear the FIFOCON bit in order to free the current
bank. If the IN Pipe is composed of multiple banks, clearing the FIFOCON bit will switch to the
next bank. The RXIN and FIFOCON bits are then updated by hardware in accordance with the
status of the new bank.
A CRC error can occur during IN stage if the USB controller detects a bad received packet. In
this situation, the STALLEDI/CRCERRI interrupt is triggered. This does not prevent the RXINI
interrupt from being triggered.
Example with 1 IN data bank
Example with 2 IN data banks
RXIN
FIFOCON
RXIN
FIFOCON
IN
IN
(to bank 0)
(to bank 0)
DATA
DATA
HW
HW
ACK
ACK
SW
SW
read data from CPU
read data from CPU
IN
BANK 0
BANK 0
(to bank 1)
DATA
SW
SW
IN
HW
ACK
(to bank 0)
read data from CPU
SW
DATA
BANK 1
HW
ACK
SW
read data from CPU
BANK 0
7593K–AVR–11/09

Related parts for AT90USB647