TMPM380FWFG Toshiba, TMPM380FWFG Datasheet - Page 388

no-image

TMPM380FWFG

Manufacturer Part Number
TMPM380FWFG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM380FWFG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
128K
Rom Type
Flash
Ram (kbytes)
12K
Number Of Pins
100
Package
LQFP(14×14)
Vcc
5V
Cpu Mhz
40
Ssp (ch) Spi
2
I2c/sio (ch)
2
Uart/sio (ch)
5
Usb
-
Can
-
Ethernet
-
External Bus Interface
N
Cs/wait Controller (ch)
-
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
-
12-bit Ad Converter
18
16-bit Timer / Counter
8
Motor / Igbt Control
Y
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
Y
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
Y
Etm Hardware Trace
2-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM380FWFG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
13.5 Operation in Each Mode
13.5.1 Mode 0 (I/O interface mode)
Mode 0 consists of two modes, the “SCLK output” mode to output synchronous clock and
the “SCLK input” mode to accept synchronous clock from an external source. The following
operational descriptions are for the case use of FIFO is disabled. For details of FIFO
operation, refer to the previous sections describing receive/transmit FIFO functions.
Transmitting data
SCLK output mode
In the SCLK output mode, if SC0MOD2<WBUF> is set to “0” and the transmit double
buffers are disabled, 8 bits of data are output from the TXD0 pin and the synchronous
clock is output from the SCLK0 pin each time the CPU writes data to the transmit buffer.
When all data is output, the INTTX0 interrupt is generated.
If SC0MOD2 <WBUF> is set to “1” and the transmit double buffers are enabled, data is
moved from Transmit Buffer to Transmit shift register when the CPU writes data to
Transmit Buffer while data transmission is halted or when data transmission from
Transmit shift register (shift register) is completed. When data is moved from Transmit
Buffer to Transmit shift register, the transmit buffer empty flag SC0MOD2 <TBEMP> is
set to “1,” and the INTTX0 interrupt is generated. If Transmit Buffer has no data to be
moved to Transmit shift register , the INTTX0 interrupt is not generated and the SCLK0
output stops.
TMPM380/M382 - 39 / 52 -
TMPM380/M382