Part Number:
LM3S3739
Manufacturer:
DSP
Quantity:
586
Part Number:
LM3S3739-IQC50
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S3739-IQC50-A0
Manufacturer:
TI
Quantity:
101
Part Number:
LM3S3739-IQC50-A0
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S3739-IQC50-A0
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LM3S3739-IQC50-A0T
Manufacturer:
Texas Instruments
Quantity:
10 000
Reset
Reset
Type
Type
ADC Processor Sample Sequence Initiate (ADCPSSI)
Base 0x4003.8000
Offset 0x028
Type WO, reset -
June 02, 2008
Bit/Field
31:4
WO
WO
3
2
1
0
31
15
-
-
WO
WO
Register 9: ADC Processor Sample Sequence Initiate (ADCPSSI), offset 0x028
This register provides a mechanism for application software to initiate sampling in the Sample
Sequencers. Sample sequences can be initiated individually or in any combination. When multiple
sequences are triggered simultaneously, the priority encodings in ADCSSPRI dictate execution
order.
30
14
-
-
WO
WO
29
13
reserved
-
-
Name
SS3
SS2
SS1
SS0
WO
WO
28
12
-
-
WO
WO
27
11
-
-
Type
WO
WO
WO
WO
WO
WO
WO
26
10
-
-
reserved
WO
WO
Reset
25
9
-
-
-
-
-
-
-
Preliminary
WO
WO
24
8
-
-
reserved
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
SS3 Initiate
Only a write by software is valid; a read of the register returns no
meaningful data. When set by software, sampling is triggered on Sample
Sequencer 3, assuming the Sequencer is enabled in the ADCACTSS
register.
SS2 Initiate
Only a write by software is valid; a read of the register returns no
meaningful data. When set by software, sampling is triggered on Sample
Sequencer 2, assuming the Sequencer is enabled in the ADCACTSS
register.
SS1 Initiate
Only a write by software is valid; a read of the register returns no
meaningful data. When set by software, sampling is triggered on Sample
Sequencer 1, assuming the Sequencer is enabled in the ADCACTSS
register.
SS0 Initiate
Only a write by software is valid; a read of the register returns no
meaningful data. When set by software, sampling is triggered on Sample
Sequencer 0, assuming the Sequencer is enabled in the ADCACTSS
register.
WO
WO
23
7
-
-
WO
WO
22
6
-
-
WO
WO
21
5
-
-
WO
WO
20
4
-
-
SS3
WO
WO
19
3
-
-
LM3S3739 Microcontroller
WO
SS2
WO
18
2
-
-
SS1
WO
WO
17
1
-
-
SS0
WO
WO
16
0
-
-
363