Specifications of IDT723644L12PF

Function
Synchronous
Memory Size
72K (2K x 36)
Data Rate
83MHz
Access Time
12ns
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-TQFP, 128-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
723644L12PF

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT723644L12PF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT723644L12PF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
TABLE 4
NOTES:
1. When a word loaded to an empty FIFO is shifted to the output register, its previous FIFO memory location is free.
2. Data in the output register does not count as a "word in FIFO memory". Since in FWFT mode, the first word written to an empty FIFO goes unrequested to the output register
3. X1 is the Almost-Empty offset for FIFO1 used by AEB. Y1 is the Almost-Full offset for FIFO1 used by AFA. Both X1 and Y1 are selected during a FIFO1 reset or port A programming.
4. The ORB and IRA functions are active during FWFT mode; the EFB and FFA functions are active in IDT Standard mode.
TABLE 5
NOTES:
1. When a word loaded to an empty FIFO is shifted to the output register, its previous FIFO memory location is free.
2. Data in the output register does not count as a "word in FIFO memory". Since in FWFT mode, the first word written to an empty FIFO goes unrequested to the output register
3. X2 is the Almost-Empty offset for FIFO2 used by AEA. Y2 is the Almost-Full offset for FIFO2 used by AFB. Both X2 and Y2 are selected during a FIFO2 reset or port A programming.
4. The ORA and IRB functions are active during FWFT mode; the EFA and FFB functions are active in IDT Standard mode.
EFB/ORB, AEB, FFB/IRB, and AFB are synchronized to CLKB. Tables 4 and
5 show the relationship of each port flag to FIFO1 and FIFO2.
EMPTY/OUTPUT READY FLAGS (EFA/ORA, EFB/ORB)
ORB) function is selected. When the Output Ready flag is HIGH, new data is
present in the FIFO output register. When the Output Ready flag is LOW, the
previous data word is present in the FIFO output register and attempted FIFO
reads are ignored.
When the Empty Flag is HIGH, data is available in the FIFO’s RAM memory
for reading to the output register. When the Empty Flag is LOW, the previous
data word is present in the FIFO output register and attempted FIFO reads are
ignored.
that reads data from its array. For both the FWFT and IDT Standard modes,
the FIFO read pointer is incremented each time a new word is clocked to its
output register. The state machine that controls an Output Ready flag monitors
a write pointer and read pointer comparator that indicates when the FIFO
memory status is empty, empty+1, or empty+2.
IDT723624/723634/723644 CMOS SyncBiFIFO™ WITH BUS-MATCHING
256 x 36 x 2, 512 x 36 x 2, 1,024 x 36 x 2
These are dual purpose flags. In the FWFT mode, the Output Ready (ORA,
In the IDT Standard mode, the Empty Flag (EFA, EFB) function is selected.
The Empty/Output Ready flag of a FIFO is synchronized to the port clock
(no read operation necessary), it is not included in the FIFO memory count.
(no read operation necessary), it is not included in the FIFO memory count.
(X1+1) to [256-(Y1+1)]
(X2+1) to [256-(Y2+1)]
(256-Y1) to 255
(256-Y2) to 255
IDT723624
IDT723624
1 to X2
1 to X1
256
256
0
0
(3)
(3)
FIFO1 FLAG OPERATION (IDT Standard and FWFT modes)
FIFO2 FLAG OPERATION (IDT Standard and FWFT modes)
Number of Words in FIFO Memory
Number of Words in FIFO Memory
(X2+1) to [512-(Y2+1)]
(X1+1) to [512-(Y1+1)]
(512-Y2) to 511
(512-Y1) to 511
IDT723634
IDT723634
1 to X2
1 to X1
512
512
0
0
(3)
(3)
(1,2)
(1,2)
(X2+1) to [1,024-(Y2+1)]
(X1+1) to [1,024-(Y1+1)]
(1,024-Y2) to 1,023
(1,024-Y1) to 1,023
IDT723644
IDT723644
1 to X2
1 to X1
13
1,024
1,024
0
0
to the FIFO output register in a minimum of three cycles of the Output Ready
flag synchronizing clock. Therefore, an Output Ready flag is LOW if a word in
memory is the next data to be sent to the FlFO output register and three cycles
of the port Clock that reads data from the FIFO have not elapsed since the time
the word was written. The Output Ready flag of the FIFO remains LOW until
the third LOW-to-HIGH transition of the synchronizing clock occurs, simulta-
neously forcing the Output Ready flag HIGH and shifting the word to the FIFO
output register.
Flag will indicate the presence of data available for reading in a minimum of two
cycles of the Empty Flag synchronizing clock. Therefore, an Empty Flag is LOW
if a word in memory is the next data to be sent to the FlFO output register and
two cycles of the port Clock that reads data from the FIFO have not elapsed
since the time the word was written. The Empty Flag of the FIFO remains LOW
until the second LOW-to-HIGH transition of the synchronizing clock occurs,
forcing the Empty Flag HIGH; only then can data be read.
clock begins the first synchronization cycle of a write if the clock transition occurs
In FWFT mode, from the time a word is written to a FIFO, it can be shifted
In IDT Standard mode, from the time a word is written to a FIFO, the Empty
A LOW-to-HIGH transition on an Empty/Output Ready flag synchronizing
(3)
(3)
EFB/ORB
EFA/ORA
Synchronized
H
H
H
H
Synchronized
L
H
H
H
H
L
to CLKB
to CLKA
COMMERCIAL TEMPERATURE RANGE
AEA
AEB
H
H
H
H
H
H
L
L
L
L
Synchronized
AFB
Synchronized
AFA
H
H
H
H
H
H
L
L
L
L
to CLKB
to CLKA
FFA/IRA
FFB/IRB
H
H
H
H
L
H
H
H
H
L