AD573 Analog Devices, AD573 Datasheet - Page 5

no-image

AD573

Manufacturer Part Number
AD573
Description
10-Bit A/D Converter
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD573
Manufacturer:
TI
Quantity:
9
Part Number:
AD5732RBREZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5734AREZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5734RBREZ
Manufacturer:
Microchip
Quantity:
1 084
Part Number:
AD5734RBREZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5737ACPZ
Manufacturer:
AD
Quantity:
101
Part Number:
AD5737ACPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD573JD
Manufacturer:
AD
Quantity:
60
Part Number:
AD573JD
Manufacturer:
AD
Quantity:
60
Part Number:
AD573JN
Manufacturer:
AVAGO
Quantity:
780
Part Number:
AD573JN
Manufacturer:
ADI
Quantity:
427
Part Number:
AD573JN
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD573JP
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD573JPZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD573SD
Manufacturer:
AD
Quantity:
650
BIPOLAR CONNECTION
To obtain the bipolar –5 V to +5 V range with an offset binary
output code, the bipolar offset control pin is left open.
A –5.000 volt signal will give a 10-bit code of 00000000 00; an
input of 0.000 volts results in an output code of 10000000 00
and +4.99 volts at the input yields the 11111111 11 code. The
nominal transfer curve is shown in Figure 6.
Note that in the bipolar mode, the code transitions are offset
1/2 LSB such that an input voltage of 0 volts 5 mV yields the
code representing zero (10000000 00). Each output code is then
centered on its nominal input voltage.
Full-Scale Calibration
Full-Scale Calibration is accomplished in the same manner as in
unipolar operation except the full scale input voltage is +4.985
volts.
Negative Full-Scale Calibration
The circuit in Figure 4a can also be used in bipolar operation to
offset the input voltage (nominally –5 V) which results in the
00000000 00 code. R2 should be omitted to obtain a symmetri-
cal range.
The bipolar offset control input is not directly TTL compatible
but a TTL interface for logic control can be constructed as
shown in Figure 7.
REV. A
Figure 6. AD573 Transfer Curve— Bipolar Operation
Figure 7. Bipolar Offset Controlled by Logic Gate
Gate Output = 1 Unipolar 0–10 V Input Range
Gate Output = 0 Bipolar 5 V Input Range
–5–
SAMPLE-HOLD AMPLIFIER CONNECTION TO THE
AD573
Many situations in high speed acquisition systems or digitizing
rapidly changing signals require a sample-hold amplifier (SHA)
in front of the A/D converter. The SHA can acquire and hold a
signal faster than the converter can perform a conversion. A
SHA can also be used to accurately define the exact point in
time at which the signal is sampled. For the AD573, a SHA can
also serve as a high input impedance buffer.
Figure 8 shows the AD573 connected to the AD582 monolithic
SHA for high speed signal acquisition. In this configuration, the
AD582 will acquire a 10 volt signal in less than 10 s with a
droop rate less than 100 V/ms.
DR goes high after the conversion is initiated to indicate that
reset of the SAR is complete. In Figure 8 it is also used to put
the AD582 into the hold mode while the AD573 begins its con-
version cycle. (The AD582 settles to final value well in advance
of the first comparator decision inside the AD573).
DR goes low when the conversion is complete placing the
AD582 back in the sample mode. Configured as shown in Fig-
ure 8, the next conversion can be initiated after a 10 s delay to
allow for signal acquisition by the AD582.
Observe carefully the ground, supply, and bypass capacitor con-
nections between the two devices. This will minimize ground
noise and interference during the conversion cycle.
GROUNDING CONSIDERATIONS
The AD573 provides separate Analog and Digital Common
connections. The circuit will operate properly with as much as
This permits more flexible control of system common bussing
and digital and analog returns.
In normal operation, the Analog Common terminal may gener-
ate transient currents of up to 2 mA during a conversion. In ad-
dition a static current of about 2 mA will flow into Analog
Common in the unipolar mode after a conversion is complete.
The Analog Common current will be modulated by the varia-
tions in input signal.
The absolute maximum voltage rating between the two com-
mons is 1 volt. It is recommended that a parallel pair of
back-to-back protection diodes be connected between the com-
mons if they are not connected locally.
200 mV of common-mode voltage between the two commons.
Figure 8. Sample-Hold Interface to the AD573
AD573

Related parts for AD573