z8fmc16100 ZiLOG Semiconductor, z8fmc16100 Datasheet - Page 261

no-image

z8fmc16100

Manufacturer Part Number
z8fmc16100
Description
Z8 Encore Motor Control Flash Mcus
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z8fmc16100AKEG
Manufacturer:
LT
Quantity:
151
Part Number:
z8fmc16100AKEG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8fmc16100AKSG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8fmc16100QKEG
Manufacturer:
TOREX
Quantity:
2 000
PS024611-0408
DBG
DBG
DBG
Write Data Memory—
This command is equivalent to the LDE and LDEI instructions. Data can be written 1 to
65536 bytes at a time (65536 bytes can be written by setting size to 0). If the device is not
in DEBUG mode or if the Read Protect option bit is enabled, the data is discarded.
DBG
DBG
DBG
DBG
DBG
DBG
Read Data Memory—
command is equivalent to the LDE and LDEI instructions. Data can be read 1 to 65536
bytes at a time (65536 bytes can be read by setting size to 0). If the device is not in
DEBUG mode, this command returns
DBG
DBG
DBG
DBG
DBG
DBG
Read Program Memory CRC—
and returns the CRC (cyclic redundancy check) of Program Memory using the 16-bit
CRC-CCITT polynomial (x
icant bit of the data is shifted through the polynomial first. The CRC is inverted when it is
transmitted. If the device is not in DEBUG mode, this command returns
CRC value. Unlike most other OCD Read commands, there is a delay from issuing of the
command until the OCD returns the data. The OCD reads the Program Memory, calculates
the CRC value, and returns the result. The delay is a function of the Program Memory size
and is approximately equal to the system clock period multiplied by the number of bytes in
the Program Memory.
DBG
DBG
DBG
Size[15:8]
Size[7:0]
1-65536 data bytes
0Ch
Data Memory Address[15:8]
Data Memory Address[7:0]
Size[15:8]
Size[7:0]
1-65536 data bytes
0Dh
Data Memory Address[15:8]
Data Memory Address[7:0]
Size[15:8]
Size[7:0]
1-65536 data bytes
0Eh
CRC[15:8]
CRC[7:0]
The Read Data Memory command reads from Data Memory. This
The Write Data Memory command writes data to Data Memory.
16
+ x
The Read Program Memory CRC command computes
12
+ x
FFh
5
+ 1). The CRC is preset to all 1s. The least-signif-
for the data.
Z8FMC16100 Series Flash MCU
On-Chip Debugger Commands
Product Specification
FFFFh
for the
249

Related parts for z8fmc16100