XR16L2552
2.25V TO 5.5V DUART WITH 16-BYTE FIFO
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Tag
LSR[3]: Receive Data Framing Error Tag
LSR[4]: Receive Break Tag
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. This bit indicates that the transmitter is ready to
accept a new character for transmission. In addition, this bit causes the UART to issue an interrupt to the host
when the THR interrupt enable is set. The THR bit is set to a logic 1 when the last data byte is transferred from
the transmit holding register to the transmit shift register. The bit is reset to logic 0 concurrently with the data
loading to the transmit holding register by the host. In the FIFO mode this bit is set when the transmit FIFO is
empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or
TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and
transmit shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
This register provides the current state of the modem interface signals, or other peripheral device that the
UART is connected. Lower four bits of this register are used to indicate the changed information. These bits
are set to a logic 1 whenever a signal from the modem changes state. These bits may be used as general
purpose inputs/outputs when they are not used with modem signals.
MSR[0]: Delta CTS# Input Flag
4.10
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was a logic 0 for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX
input returns to the idle condition, “mark” or logic 1.
Logic 0 = No FIFO error (default).
Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in the FIFO.
Logic 0 = No change on CTS# input (default).
Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).