M29W640GB NUMONYX [Numonyx B.V], M29W640GB Datasheet - Page 25

no-image

M29W640GB

Manufacturer Part Number
M29W640GB
Description
64 Mbit (8Mb x8 or 4Mb x16, Page) 3V supply Flash memory
Manufacturer
NUMONYX [Numonyx B.V]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640GB
Manufacturer:
ST
0
Part Number:
M29W640GB-70N6E
Manufacturer:
ST
0
Part Number:
M29W640GB-70NA6
Manufacturer:
ST
0
Part Number:
M29W640GB-70NA6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M29W640GB-70NA6E
Manufacturer:
ST
0
Part Number:
M29W640GB-70NA6E
Manufacturer:
ST
Quantity:
20 000
Part Number:
M29W640GB-70NB6
Manufacturer:
ST
0
Part Number:
M29W640GB-70NB6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M29W640GB6AZA6
Manufacturer:
ST
Quantity:
20 000
M29W640GH, M29W640GL, M29W640GT, M29W640GB
4.1.5
4.1.6
Block Erase command
The Block Erase command can be used to erase a list of one or more blocks. Six Bus Write
operations are required to select the first block in the list. Each additional block in the list can
be selected by repeating the sixth Bus Write operation using the address of the additional
block. The Block Erase operation starts the Program/Erase Controller about 50µs after the
last Bus Write operation. Once the Program/Erase Controller starts it is not possible to
select any more blocks. Each additional block must therefore be selected within 50µs of the
last block. The 50µs timer restarts when an additional block is selected. The Status Register
can be read after the sixth Bus Write operation. See the Status Register section for details
on how to identify if the Program/Erase Controller has started the Block Erase operation.
If any selected blocks are protected then these are ignored and all the other selected blocks
are erased. If all of the selected blocks are protected the Block Erase operation appears to
start but will terminate within about 100µs, leaving the data unchanged. No error condition is
given when protected blocks are ignored.
During the Block Erase operation the memory will ignore all commands except the Erase
Suspend command. Typical block erase times are given in
and endurance
the Status Register on the Data Inputs/Outputs. See the section on the Status Register for
more details.
After the Block Erase operation has completed the memory will return to the Read Mode,
unless an error has occurred. When an error occurs the memory will continue to output the
Status Register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
The Block Erase Command sets all of the bits in the unprotected selected blocks to ’1’. All
previous data in the selected blocks is lost.
Refer to
ac waveforms.
Erase Suspend command
The Erase Suspend Command may be used to temporarily suspend a Block Erase
operation and return the memory to Read mode. The command requires one Bus Write
operation.
The Program/Erase Controller will suspend within the Erase Suspend Latency time of the
Erase Suspend Command being issued. Once the Program/Erase Controller has stopped
the memory will be set to Read mode and the Erase will be suspended. If the Erase
Suspend command is issued during the period when the memory is waiting for an additional
block (before the Program/Erase Controller starts) then the Erase is suspended immediately
and will start immediately when the Erase Resume Command is issued. It is not possible to
select any further blocks to erase after the Erase Resume.
During Erase Suspend it is possible to Read and Program cells in blocks that are not being
erased; both Read and Program operations behave as normal on these blocks. If any
attempt is made to program in a protected block or in the suspended block then the Program
command is ignored and the data remains unchanged. The Status Register is not read and
no error condition is given. Reading from blocks that are being erased will output the Status
Register.
Figure 8: Chip/Block Erase waveforms (8-bit mode)
cycles. All Bus Read operations during the Block Erase operation will output
Table 12: Program, Erase times
for a description of Block Erase
Command Interface