FDC37C669_07 SMSC [SMSC Corporation], FDC37C669_07 Datasheet - Page 35

no-image

FDC37C669_07

Manufacturer Part Number
FDC37C669_07
Description
PC 98/99 Compliant Super I/O Floppy Disk Controller with Infrared Support
Manufacturer
SMSC [SMSC Corporation]
Datasheet
BIT NO.
7
6
5
4
3
2
1
0
EN
DE
OR
ND
NW
MA
SYMBOL
End of
Cylinder
Data Error
Overrun/
Underrun
No Data
Not Writeable WP pin became a "1" while the FDC is executing a
Missing
Address Mark
NAME
Table 15 - Status Register 1
The FDC tried to access a sector beyond the final
sector of the track (255D). Will be set if TC is not
issued after Read or Write Data command.
Unused. This bit is always "0".
The FDC detected a CRC error in either the ID field or
the data field of a sector.
Becomes set if the FDC does not receive CPU or DMA
service within the required time interval, resulting in
data overrun or underrun.
Unused. This bit is always "0".
Any one of the following:
1. Read Data, Read Deleted Data command - the
2. Read ID command - the FDC cannot read the ID
3. Read A Track command - the FDC cannot find the
Write Data, Write Deleted Data, or Format A Track
command.
Any one of the following:
1. The FDC did not detect an ID address mark at the
2. The FDC cannot detect a data address mark or a
35
FDC did not find the specified sector.
field without an error.
proper sector sequence.
specified track after encountering the index pulse
from the IDX pin twice.
deleted data address mark on the specified track.
DESCRIPTION