BTS410F2E3062A INFINEON [Infineon Technologies AG], BTS410F2E3062A Datasheet - Page 4

no-image

BTS410F2E3062A

Manufacturer Part Number
BTS410F2E3062A
Description
Smart Highside Power Switch
Manufacturer
INFINEON [Infineon Technologies AG]

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS410F2E3062A
Manufacturer:
INF
Quantity:
5 309
Part Number:
BTS410F2E3062A
Manufacturer:
INFINEON
Quantity:
12 000
Protection Functions
( max 450 s if V
9
10
11
Semiconductor Group
Parameter and Conditions
at T
Initial peak short circuit current limit (pin 3 to 5)
Overload shutdown current limit
Short circuit shutdown delay after input pos. slope
Output clamp (inductive load switch off)
at V
Short circuit shutdown detection voltage(pin 3 to 5) V
Thermal overload trip temperature
Thermal hysteresis
Reverse battery (pin 3 to 1)
Diagnostic Characteristics
Open load detection current
)
) Short circuit current limit for max. duration of t
) Requires 150
min value valid only, if input "low" time exceeds 60 s
V
V
(on-condition)
ON
j
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are not
designed for continuous repetitive operation.
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 7).
ON
OUT
= 25 °C, V
> V
= 8 V, T
= V
ON(SC)
bb
bb
- V
,
= 12 V unless otherwise specified
j
= T
ON(CL)
ON
resistor in GND connection. The reverse load current through the intrinsic drain-source
jt
> V
(see timing diagrams, page 11)
9
I
)
L
ON(SC)
= 40 mA, T
I
L
= 1 A, T
11
)
)
T
T
j
j
j
=-40..+150°C:
=-40..+150°C: V
=-40..+150°C:
j
=-40 ..150°C:
T
j
T
=+150°C:
d(SC) max
T
j
j
=-40°C:
=25°C:
4
10
)
,
=450 s, prior to shutdown
I
I
t
T
-V
I
Symbol
L(SCp)
L(SCr)
d(SC)
L (OL)
jt
T
ON(CL)
ON(SC)
bb
jt
150
min
4.0
3.5
2.0
61
--
--
--
--
--
--
2
Values
5.5
3.5
2.7
8.5
typ
68
10
--
--
--
--
--
--
BTS 410 F2
max
450
150
7.5
2003-Oct-01
11
10
73
75
32
--
--
--
--
Unit
mA
°C
A
A
V
V
K
V
s

Related parts for BTS410F2E3062A