TLE5205-2_07 INFINEON [Infineon Technologies AG], TLE5205-2_07 Datasheet - Page 8

no-image

TLE5205-2_07

Manufacturer Part Number
TLE5205-2_07
Description
5-A H-Bridge for DC-Motor Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
2
Various errors as listed in the table “Diagnosis” are detected. Short circuits and overload
result in turning off the output stages after a delay
simultaneously [EF = L]. Changing the inputs to a state where the fault is not detectable
resets the error flag (input toggling) with the exception of short circuit from OUT1 to
OUT2 (load short circuit).
Flag
Open circuit between OUT1 and OUT2
Short circuit from OUT1 to OUT2
Short circuit from OUT1 to GND
Short circuit from OUT2 to GND
Short circuit from OUT1 to
Short circuit from OUT2 to
Overtemperature or undervoltage
IN: 0 = Logic LOW
Data Sheet
1 = Logic HIGH
Diagnosis
OUT: Z = Output in tristate condition
V
V
S
S
L = Output in sink condition
H = Output in source condition
=
V
S
/2 due to internal Pull-up/down resistors
IN1 IN2 OUT1 OUT2 EF Remarks
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
8
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
H
L
L
Z
V
V
L
Z
GND
GND
GND
GND
H
L
L
L
V
V
V
V
H
L
H
H
Z
Z
Z
Z
S
S
S
S
S
S
/2
/2
t
L
H
L
Z
V
V
L
Z
L
H
L
L
GND
GND
GND
GND
L
H
H
H
V
V
V
V
Z
Z
Z
Z
dSD
S
S
S
S
S
S
/2
/2
and setting the error flag
1
1
1
0
0
0
1
1
0
1
1
1
1
0
1
1
1
0
0
1
0
1
0
1
0
0
0
0
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Not detectable
Rev. 1.1, 2007-07-31
EF:
TLE 5205-2
1 = No error
0 = Error
Diagnosis
Nr.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Related parts for TLE5205-2_07