SCD1284 INTEL [Intel Corporation], SCD1284 Datasheet - Page 91

no-image

SCD1284

Manufacturer Part Number
SCD1284
Description
IEEE 1284-Compatible Parallel Interface Controller with Two High-Speed Asynchronous Serial Ports
Manufacturer
INTEL [Intel Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCD128410QCE
Manufacturer:
INTEL
Quantity:
20 000
Datasheet
This procedure is also used as part of a diagnostic test suite. The device completes internal
initialization within 500 sec. A timer (software or hardware) detects when the operation is not
completed within that time and cues if the device is functional.
Internal firmware uses this operation to flag completion of the reset procedure. After the reset
is issued, the GFRCR is one of the first registers cleared and it is the last one set before normal
runtime code execution begins. The initialization routine must wait for this register to become
non-zero before it begins any other programming of CD1284 registers. If the CPU is
sufficiently fast, it could begin testing the GFRCR before the MPU clears it. The assumption
could be made that the CD1284 has completed internal initialization when, in fact, it has not
even started. To avoid this error, the CPU should look for the GFRCR to change to ‘0.’ It
should then look to the current revision code. Alternatively, the CPU can clear the GFRCR just
prior to issuing the global reset command and then poll for the correct revision code. This is
useful in slow systems that cannot guarantee that the CPU can check the register after it is
cleared or before it is loaded with the revision code.