MAX11014BGTM+ Maxim Integrated, MAX11014BGTM+ Datasheet - Page 42

no-image

MAX11014BGTM+

Manufacturer Part Number
MAX11014BGTM+
Description
Special Purpose Amplifiers Auto RF MESFET Amp Drain-Current Cntrlr
Manufacturer
Maxim Integrated
Series
MAX11014, MAX11015r
Datasheet

Specifications of MAX11014BGTM+

Rohs
yes
Common Mode Rejection Ratio (min)
90 dB
Operating Supply Voltage
0.5 V to 11 V
Supply Current
2.8 mA
Maximum Power Dissipation
2162.2 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFN-48
Available Set Gain
13.98 dB
Automatic RF MESFET Amplifier
Drain-Current Controllers
Table 13. ALMSCFG (Read/Write)
42
BIT NAME
VALARM2
TALARM2
VALARM1
TALARM1
IALARM2
IALARM1
VWIN2
TWIN2
VWIN1
TWIN1
IWIN2
IWIN1
______________________________________________________________________________________
X
DATA BIT
D15–D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
RESET STATE
X
0
0
0
0
0
0
0
0
0
0
0
0
Don’t care.
Channel 2 GATE voltage ALARM bit. Set to 1 to enable the ALARM functionality for
GATE2 voltage measurements. Set to 0 to disable the ALARM functionality for GATE2
voltage measurements.
Channel 2 GATE voltage windowing bit. Set to 1 to monitor the GATE2 voltage with the
ALARM comparator in windowing mode. Set to 0 to monitor the GATE2 voltage with the
ALARM comparator in hysteresis mode.
Channel 2 temperature ALARM bit. Set to 1 to enable the ALARM functionality for
channel 2 temperature measurements. Set to 0 to disable the ALARM functionality for
channel 2 temperature measurements.
Channel 2 temperature windowing bit. Set to 1 to monitor the channel 2 temperature
with the ALARM comparator in windowing mode. Set to 0 to monitor the channel 2
temperature with the ALARM comparator in hysteresis mode.
Channel 2 sense voltage ALARM bit. Set to 1 to enable the ALARM functionality for
channel 2 sense voltage measurements. Set to 0 to disable the ALARM functionality for
channel 2 sense voltage measurements.
Channel 2 sense voltage windowing bit. Set to 1 to monitor the channel 2 sense
voltage with the ALARM comparator in windowing mode. Set to 0 to monitor the
channel 2 sense voltage with the ALARM comparator in hysteresis mode.
Channel 1 GATE voltage ALARM bit. Set to 1 to enable the ALARM functionality for
GATE1 voltage measurements. Set to 0 to disable the ALARM functionality for GATE1
voltage measurements.
Channel 1 GATE voltage windowing bit. Set to 1 to monitor the GATE1 voltage with the
ALARM comparator in windowing mode. Set to 0 to monitor the GATE1 voltage with the
ALARM comparator in hysteresis mode.
Channel 1 temperature ALARM bit. Set to 1 to enable the ALARM functionality for
channel 1 temperature measurements. Set to 0 to disable the ALARM functionality for
channel 1 temperature measurements.
Channel 1 temperature windowing bit. Set to 1 to monitor the channel 1 temperature
with the ALARM comparator in windowing mode. Set to 0 to monitor the channel 1
temperature with the ALARM comparator in hysteresis mode.
Channel 1 sense voltage ALARM bit. Set to 1 to enable the ALARM functionality for
channel 1 sense voltage measurements. Set to 0 to disable the ALARM functionality for
channel 1 sense voltage measurements.
Channel 1 sense voltage windowing bit. Set to 1 to monitor the channel 1 sense
voltage with the ALARM comparator in windowing mode. Set to 0 to monitor the
channel 1 sense voltage with the ALARM comparator in hysteresis mode.
FUNCTION