MAX11014BGTM+ Maxim Integrated, MAX11014BGTM+ Datasheet - Page 51

no-image

MAX11014BGTM+

Manufacturer Part Number
MAX11014BGTM+
Description
Special Purpose Amplifiers Auto RF MESFET Amp Drain-Current Cntrlr
Manufacturer
Maxim Integrated
Series
MAX11014, MAX11015r
Datasheet

Specifications of MAX11014BGTM+

Rohs
yes
Common Mode Rejection Ratio (min)
90 dB
Operating Supply Voltage
0.5 V to 11 V
Supply Current
2.8 mA
Maximum Power Dissipation
2162.2 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFN-48
Available Set Gain
13.98 dB
Table 27. ALMFLAG (Read)
BIT NAME
HIGH-V2
HIGH-V1
HIGH-T2
HIGH-T1
LOW-V2
HIGH-I2
LOW-T2
LOW-V1
HIGH-I1
LOW-T1
LOW-I2
LOW-I1
X
______________________________________________________________________________________
DATA BIT
D15–D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
RESET STATE
Automatic RF MESFET Amplifier
X
0
0
0
0
0
0
0
0
0
0
0
0
Don’t care.
HIGH-V2 is set to 1 when the GATE2 voltage exceeds the high threshold
setting. HIGH-V2 is reset to 0 by either a read of the ALARM flag register
or a software clear command.
LOW-V2 is set to 1 when the GATE2 voltage decreases below the low
threshold setting. LOW-V2 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
HIGH-I2 is set to 1 when the channel 2 sense voltage exceeds the high
threshold setting. HIGH-I2 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
LOW-I2 is set to 1 when the channel 2 sense voltage decreases below
the low threshold setting. LOW-I2 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
HIGH-T2 is set to 1 when the channel 2 external temperature exceeds
the high threshold setting. HIGH-T2 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
LOW-T2 is set to a 1 when the channel 2 external temperature
decreases below the low threshold setting. LOW-T2 is reset to 0 by
either a read of the ALARM flag register or a software clear command.
HIGH-V1 is set to 1 when the GATE1 voltage exceeds the high threshold
setting. HIGH-V1 is reset to 0 by either a read of the ALARM flag register
or a software clear command.
LOW-V1 is set to 1 when the GATE1 voltage decreases below the low
threshold setting. LOW-V1 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
HIGH-I1 is set to 1 when the channel 1 sense voltage exceeds the high
threshold setting. HIGH-I1 is reset to 0 by either a read of the ALARM
flag register or a software clear command.
LOW-I1 is set to 1 when the channel 1 sense voltage decreases below
the low threshold setting. LOW-I1 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
HIGH-T1 is set to 1 when the channel 1 external temperature exceeds
the high threshold setting. HIGH-T1 is reset to 0 by either a read of the
ALARM flag register or a software clear command.
LOW-T1 is set to a 1 when the channel 1 external temperature
decreases below the low threshold setting. LOW-T1 is reset to 0 by
either a read of the ALARM flag register or a software clear command.
Drain-Current Controllers
FUNCTION
51