ATMEGA16U2-16AU Atmel, ATMEGA16U2-16AU Datasheet - Page 126

no-image

ATMEGA16U2-16AU

Manufacturer Part Number
ATMEGA16U2-16AU
Description
8-bit Microcontrollers - MCU 16K Flash
Manufacturer
Atmel
Datasheet

Specifications of ATMEGA16U2-16AU

Product Category
8-bit Microcontrollers - MCU
Rohs
yes
Core
AVR
Data Bus Width
8 bit
Program Memory Size
16 KB
Data Ram Size
1.25 KB
Data Rom Size
512 B
Program Memory Type
Flash
Factory Pack Quantity
1250
7799D–AVR–11/10
the maximum resolution is 16-bit (ICRn or OCRnA set to MAX). The PWM resolution in bits can
be calculated using the following equation:
In phase and frequency correct PWM mode the counter is incremented until the counter value
matches either the value in ICRn (WGMn[3:0] = 8), or the value in OCRnA (WGMn[3:0] = 9). The
counter has then reached the TOP and changes the count direction. The TCNTn value will be
equal to TOP for one timer clock cycle. The timing diagram for the phase correct and frequency
correct PWM mode is shown on
PWM mode when OCRnA or ICRn is used to define TOP. The TCNTn value is in the timing dia-
gram shown as a histogram for illustrating the dual-slope operation. The diagram includes non-
inverted and inverted PWM outputs. The small horizontal line marks on the TCNTn slopes repre-
sent compare matches between OCRnx and TCNTn. The OCnx Interrupt Flag will be set when a
compare match occurs.
Figure 16-9. Phase and Frequency Correct PWM Mode, Timing Diagram
The Timer/Counter Overflow Flag (TOVn) is set at the same timer clock cycle as the OCRnx
Registers are updated with the double buffer value (at BOTTOM). When either OCRnA or ICRn
is used for defining the TOP value, the OCnA or ICFn Flag set when TCNTn has reached TOP.
The Interrupt Flags can then be used to generate an interrupt each time the counter reaches the
TOP or BOTTOM value.
When changing the TOP value the program must ensure that the new TOP value is higher or
equal to the value of all of the Compare Registers. If the TOP value is lower than any of the
Compare Registers, a compare match will never occur between the TCNTn and the OCRnx.
As
cal in all periods. Since the OCRnx Registers are updated at BOTTOM, the length of the rising
and the falling slopes will always be equal. This gives symmetrical output pulses and is therefore
frequency correct.
Figure 16-9
TCNTn
OCnx
OCnx
Period
shows the output generated is, in contrast to the phase correct mode, symmetri-
1
Figure
R
PFCPWM
2
16-9. The figure shows phase and frequency correct
=
3
log
---------------------------------- -
ATmega8U2/16U2/32U2
log
TOP
2  
+
1
4
OCnA Interrupt Flag Set
or ICFn Interrupt Flag Set
(Interrupt on TOP)
(COMnx1:0 = 2)
(COMnx1:0 = 3)
OCRnx/TOP Updateand
TOVn Interrupt Flag Set
(Interrupt on Bottom)
126

Related parts for ATMEGA16U2-16AU