ICE2A765P Infineon Technologies, ICE2A765P Datasheet - Page 16

IC OFFLINE CTRLR SMPS CM TO220

ICE2A765P

Manufacturer Part Number
ICE2A765P
Description
IC OFFLINE CTRLR SMPS CM TO220
Manufacturer
Infineon Technologies
Series
CoolSET®F2r
Datasheet

Specifications of ICE2A765P

Package / Case
TO-220-6 Formed Leads
Output Isolation
Isolated
Frequency Range
93 ~ 107kHz
Voltage - Input
8.5 ~ 22 V
Voltage - Output
650V
Power (watts)
240W
Operating Temperature
-40°C ~ 150°C
Duty Cycle (max)
77 %
Output Voltage
650 V (Max)
Output Current
7000 mA (Max)
Mounting Style
Through Hole
Switching Frequency
107 KHz
Maximum Operating Temperature
+ 150 C
Fall Time
30 ns
Minimum Operating Temperature
- 40 C
Rise Time
30 ns
Synchronous Pin
No
Topology
Flyback
Number Of Outputs
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ICE2A765PIN
ICE2A765PX
ICE2A765PXK
ICE2A765PXTIN
ICE2A765PXTIN
SP000013794

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICE2A765P
Manufacturer:
INFINEON
Quantity:
3
Part Number:
ICE2A765P
Manufacturer:
ST
0
Part Number:
ICE2A765P
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
ICE2A765P
Quantity:
417
Part Number:
ICE2A765P2XK
Manufacturer:
INFINEON
Quantity:
655
But the Soft-Start Phase must be finished within the
Start Up Phase to force the voltage at pin FB below the
failure detection threshold of 4.8V.
3.8.2
Figure 23
Figure 23 shows the Auto Restart Mode for open loop
and no load condition. In case of this failure mode the
converter output voltage increases and also VCC. An
additional protection by the comparators C1, C2 and
the AND-gate G1 is implemented to consider this
failure mode (see Figure 24).The overvoltage detection
is provided by Comparator C1 only in the first time
during the Soft-Start Phase till the Soft-Start voltage
exceeds the threshold of the Comparator C2 at 4.0V
and the voltage at pin FB is above 4.8V. When VCC
exceeds 16.5V during the overvoltage detection phase
C1 can set the Error-Latch and the Burst Phase during
Auto Restart Mode is finished earlier. In that case
T
Version 2.6
Burst2
16.5V
13.5V
Driver
SoftS
8.5V
5.3V
4.0V
VCC
4.8V
FB
is shorter than T
5µs Blanking
Open loop & no load condition
Overvoltage due to Open Loop with
No Load
Auto Restart Mode
Detection
Failure
Detection Phase
Overvoltage
Soft-Start
Soft-Start Phase
Overvoltage Detection
T
Burst2
. By means of C2 the
T
Restart
t
t
t
t
16
normal operation mode is prevented from overvoltage
detection due to varying of VCC concerning the
regulation of the converter output. When the voltage
V
deactivated.
Figure 24
3.8.3
Thermal Shut Down is latched by the Error-Latch when
junction temperature T
exceeding an internal threshold of 140°C. In that case
the IC switches in Auto Restart Mode.
Note:
SoftS
SoftS
C
Soft-Start
is above 4.0V the overvoltage detection by C1 is
All the values which are mentioned in the
functional description are typical. Please refer
to Electrical Characteristics for min/max limit
values.
6.5V
Thermal Shut Down
Overvoltage Detection
T1
R
VCC
Soft-Start
16.5V
4.0V
Functional Description
j
Power Up Reset
C1
C2
of the pwm controller is
CoolSET™-F2
G1
25 Dec 2006
Error Latch

Related parts for ICE2A765P