ICE3A2565 Infineon Technologies, ICE3A2565 Datasheet - Page 14

no-image

ICE3A2565

Manufacturer Part Number
ICE3A2565
Description
IC OFFLINE CTRLR SMPS CM 8DIP
Manufacturer
Infineon Technologies
Series
CoolSET®F3r
Datasheets

Specifications of ICE3A2565

Package / Case
8-DIP (0.300", 7.62mm)
Output Isolation
Isolated
Frequency Range
92 ~ 108kHz
Voltage - Input
8.5 ~ 22 V
Voltage - Output
650V
Power (watts)
68W
Operating Temperature
-25°C ~ 130°C
Output Voltage
650V
No. Of Outputs
1
Supply Voltage Range
8.5V To 21V
Voltage Regulator Case Style
DIP
No. Of Pins
8
Operating Temperature Range
-40°C To +150°C
Termination
RoHS Compliant
Input Voltage
265VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ICE3A2565X
ICE3A2565XK
SP000015075

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICE3A2565
Manufacturer:
PHILIPS
Quantity:
32
Part Number:
ICE3A2565
Manufacturer:
INFINEON
Quantity:
80
Figure 19
3.8
An overload, open loop and overvoltage detection is
integrated within the Protection Unit. These three
failure modes are latched by an Error-Latch. Additional
thermal shutdown is latched by the Error-Latch. In case
of those failure modes the Error-Latch is set after a
blanking time of 5µs and the CoolMOS™ is shut down.
That blanking prevents the Error-Latch from distortions
caused by spikes during operation mode.
3.8.1
Figure 20 shows the Auto Restart Mode in case of
overload or open loop with normal load. The detection
of open loop or overload is provided by the Comparator
C3, C4 and the AND-gate G2 (see Figure 21). The
detection is activated by C4 when the voltage at pin
SoftS exceeds 5.3V. Till this time the IC operates in the
Soft-Start Phase. After this phase the comparator C3
can set the Error-Latch in case of open loop or overload
which leads the feedback voltage V
threshold of 4.8V. After latching VCC decreases till
8.5V and inactivates the IC. At this time the external
Soft-Start capacitor is discharged by the internal
transistor T1 due to Power Down Reset. When the IC
is inactive V
the Capacitor C
R
Reset and the external Soft-Start capacitor C
charged by the internal pullup resistor R
the Soft-Start Phase which ends when the voltage at
pin SoftS exceeds 5.3V the detection of overload and
open loop by C3 and G2 is inactive. In this way the Start
Up Phase is not detected as an overload.
Datasheet V4.5
Start-Up
5 V
V
G a te
. Then the Error-Latch is reset by Power Up
Protection Unit (Auto Restart Mode)
Overload / Open Loop with Normal
Load
VCC
Gate Rising Slope
ca . t = 1 3 0 n s
increases till V
VCC
by means of the Start-Up Resistor
CCon
= 13.5V by charging
FB
Soft-Start
to exceed the
Soft-Start
. During
t
is
14
Figure 20 Auto Restart Mode
Figure 21 FB-Detection
S o ftS
F B
Driver
SoftS
VCC
13.5V
C
4.8V
5.3V
8.5V
FB
S oft-S ta rt
6 .5 V
Overload / Open Loop with Normal Load
R
T 1
5µs Blanking
S o ft-S tart
R
6 .5 V
F B
Detection
Failure
Soft-Start Phase
5 .3 V
4 .8 V
P o w e r U p R e se t
Functional Description
T
C 4
C 3
Burst1
CoolSET™-F2
T
Restart
G 2
E rro r-L a tc h
Jan 2004
t
t
t
t

Related parts for ICE3A2565