TLE6220GP Infineon Technologies, TLE6220GP Datasheet
TLE6220GP
Specifications of TLE6220GP
SP000308873
TLE6220GPINTR
TLE6220GPNT
TLE6220GPT
TLE6220GPT
TLE6220GPXT
Available stocks
Related parts for TLE6220GP
TLE6220GP Summary of contents
Page 1
Smart Quad Low-Side Switch Features Short Circuit Protection Overtemperature Protection Overvoltage Protection 8 bit Serial Data Input and Diag- nostic Output (SPI protocol) Direct Parallel Control of Four Channels for PWM Applications Cascadable with Other Quad Switches Low Quiescent Current ...
Page 2
Pin Description Pin Symbol 1 GND 2 IN2 3 OUT1 RESET PRG Program (inputs high or low active) 8 OUT2 9 IN1 10 GND 11 GND 12 IN4 13 OUT3 14 FAULT 15 SO ...
Page 3
Maximum Ratings for T Parameter Supply Voltage Continuous Drain Source Voltage (OUT1...OUT4) Input Voltage, All Inputs and Data Lines Load Dump Protection V Load Dump With Automotive Injector Valve =400ms; IN ...
Page 4
Electrical Characteristics Parameter and Conditions V = 4 ° 150 °C ; Reset = (unless otherwise specified) 1. Power Supply, Reset 4 Supply Voltage 5 Supply Current ...
Page 5
Electrical Characteristics cont. Parameter and Conditions V = 4 ° 150 °C ; Reset = (unless otherwise specified) 5. Diagnostic Functions Open Load Detection Voltage Output Pull ...
Page 6
Functional Description The TLE 6220 quad-low-side power switch which provides a serial peripheral inter- face (SPI) to control the 4 power DMOS switches, as well as diagnostic feedback. The power transistors are protected against short to V ...
Page 7
SCLK - Serial Clock. The system clock pin clocks the internal shift register of the TLE 6220 GP. The serial input (SI) accepts data into the input shift register on the falling edge of SCLK while the serial output (SO) ...
Page 8
Serial Control of the Outputs: SPI protocol Each output is independently controlled by an output latch and a common reset line, which disables all four outputs. The Serial Input (SI) is read on the falling edge of the serial clock. ...
Page 9
command: No change of the output state; reading back of inputs and 1bit diagnosis SO diagnosis: No fault, normal function ...
Page 10
The OR-function is the default Boolean operation if the device restarts after a Reset, or when the supply voltage is switched on for the first time. If the OR operation is programmed it is latched until it is overwritten by ...
Page 11
Diagnostics - Fault pin. There is a general fault pin (open drain) which shows a high to low transi- FAULT tion as soon as an error occurs for any one of the four channels. This fault indication can be used ...
Page 12
CS SCLK Control Bits 6 4444 MSB Outputs Figure 2: Serial Interface CS 0 SCKH t lead SCLK Figure 3: Input Timing Diagram 0.7 V SCLK t valid ...
Page 13
80% 20% Figure 5: Power Outputs Application Circuit VS µC e.g. C166 MTSR MRST CLK P xy V2.2 t OFF V BB 10k VS PRG OUT1 FAULT OUT2 RESET IN1 OUT4 IN2 TLE IN3 ...
Page 14
Typical electrical Characteristics Drain-Source on-resistance DS(ON Typical Drain- Source ON-Resistance 0,58 0,53 0,48 0,43 0,38 0,33 0,28 0,23 -50 -25 0 Typical ON Resistance versus Junction-Temperature Figure 6 : ...
Page 15
Parallel SPI Configuration Engine Management Application TLE 6230 GP in combination with TLE 6240 GP (16-fold switch) for relays and general purpose loads and TLE 6220 GP (quad switch) to drive the injector valves. This arrangement covers the numerous loads ...
Page 16
Package and Ordering Code (all dimensions in mm DSO - 20 TLE 6220 13 1.27 1. 45° ...
Page 17
Green Product (RoHS compliant) To meet the world-wide customer requirements for environmentally friendly products and to be com- pliant with government regulations the device is available as a green product. Green products are RoHS-Compliant (i.e Pb-free finish on leads and ...
Page 18
Revision History Version Date V2.1 -> 18.11.2009 V2.2 V2.0 -> 20.04.2007 V2.1 V1.1 -> 20.05.2003 V2.0 V1.1 28.08.2007 V2.2 Changes Package changed to PG-DSO-20 Ordering code removed Ordering Code removed Layout Changes Correct green package name implemented P-DSO-20-12 à PG-DSO- ...
Page 19
... Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life ...