AMIS30621C6217RG ON Semiconductor, AMIS30621C6217RG Datasheet - Page 21

no-image

AMIS30621C6217RG

Manufacturer Part Number
AMIS30621C6217RG
Description
IC MOTOR STEPPER DVR/CTLR 20SOIC
Manufacturer
ON Semiconductor
Type
Micro Stepping Motor Driverr
Datasheet

Specifications of AMIS30621C6217RG

Number Of Outputs
4
Voltage - Supply
6.5 V ~ 29 V
Operating Temperature
-40°C ~ 165°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (7.5mm Width)
Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
6.5 V to 29 V
Supply Current
800 mA
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Applications
-
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Main Control and Register, OTP memory + ROM
Power−up Phase
10ms. After this phase, the AMIS−30621 is in standby
mode, ready to receive LIN messages and execute the
associated commands. After power−up, the registers and
flags are in the reset state, while some of them are being
loaded with the OTP memory content (see Table 19).
Reset
micro−cut on pin V
level), the H−bridges will be in high−impedance mode, and
the registers and flags will have a predetermined value. This
is documented in Tables 19 and 20.
Soft Stop
with a deceleration phase. At the end of this action, the
register <TagPos> is loaded with the value contained in
register <ActPos>, see Table 19). The circuit is then ready
to execute a new positioning command, provided thermal
and electrical conditions allow for it.
Power up phase of the AMIS−30621 will not exceed
After power−up, or after a reset occurrence (e.g. a
A soft stop is an immediate interruption of a motion, but
Figure 13. Simplified Timing Diagram Showing the Change in States for SWI Comparator
BB
SWI_Cmp
“R”−Comp
has made V
DriveHS
DriveLS
ActPos
ESW
R
th
DD
to go below V
Tsw = 1024 ms
0
Tsw_on = 64 ms
DDReset
http://onsemi.com
60 ms
1
21
512 ms
Sleep Mode
driven to its secure position. After which, the circuit is
completely powered down, apart from the LIN receiver,
which remains active to detect a dominant state on the bus.
In case sleep mode is entered while a motion is ongoing, a
transition will occur towards secure position as described in
Positioning and Motion Control provided <SecPos> is
enabled. Otherwise, <SoftStop> is performed.
Sleep mode can be entered in the following cases:
is received (this valid frame can be addressed to another
slave).
When entering sleep mode, the stepper−motor can be
The circuit will return to normal mode if a valid LIN frame
The circuit receives a LIN frame with identifier 0x3C
and first data byte containing 0x00, as required by LIN
specification rev 1.3. See also Sleep in the LIN
Application Command section.
In case the LIN bus is and remains inactive (or is lost)
during more than 25000 time slots (1.30 s at
19.2 kbit/s), a time−out signal switches the circuit to
sleep mode.
1
1
t
t
t
t
t
t