AMIS30621C6217RG ON Semiconductor, AMIS30621C6217RG Datasheet - Page 36

no-image

AMIS30621C6217RG

Manufacturer Part Number
AMIS30621C6217RG
Description
IC MOTOR STEPPER DVR/CTLR 20SOIC
Manufacturer
ON Semiconductor
Type
Micro Stepping Motor Driverr
Datasheet

Specifications of AMIS30621C6217RG

Number Of Outputs
4
Voltage - Supply
6.5 V ~ 29 V
Operating Temperature
-40°C ~ 165°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (7.5mm Width)
Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
6.5 V to 29 V
Supply Current
800 mA
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Applications
-
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Writing Frames
the slave nodes by means of a writing frame. According to
the LIN specification, identifiers are to be used to determine
to <ID5>, conform LIN1.3 specification. <ID6> = <ID0> ⊗
<ID1> ⊗ <ID2> ⊗ <ID4> (even parity) and <ID7> =
NOT(<ID1> ⊗ <ID3> ⊗ <ID4> ⊗ <ID5>) (odd parity).
within the data field in order to use less identifiers. One can
NOTE:
following:
NOTE:
ID0 ID1 ID2 ID3 ID4 ID5 ID6 ID7
ID0
0x3C
The LIN master sends commands and/or information to
<ID6> and <ID7> are used for parity check over <ID0>
Another possibility is to determine the specific action
The writing frames used with the AMIS−30621 are the
ID5
Type #1: General purpose two or four data bytes
Type #2: two, four or eight data bytes writing frame
ID
0
0
1
1
ID1 ID2 ID3 ID4 ID5 ID6 ID7
Bit 7 of Data byte 1 must be at ‘1’ since the LIN specification requires that contents from 0x00 to 0x7F must be reserved for
broadcast messages (0x00 being for the “Sleep” message). See also LIN command Sleep
<ID4> and <ID5> indicate the number of data bytes.
00
writing frame with a dynamically assigned
identifier. This type is dedicated to short writing
actions when the bus load can be an issue. They
are used to provide direct command to one
((<Broad> = ‘1’) or all the slave nodes
with an identifier dynamically assigned to an
application command, regardless of the
physical address of the circuit.
Data Byte 1
Identifier Byte
AppCmd
ID4
ID
0
1
0
1
1
Data Byte 2
Ndata (number of data fields)
command
2
2
4
8
Data Byte 3
physical
address
command
phys. address
Data1
http://onsemi.com
Data Byte 4
Data Byte 1
36
Physical address
a specific action. If a physical addressing is needed, then
some bits of the data field can be dedicated to this, as
illustrated in the example below.
for example use the reserved identifier 0x3C and take
advantage of the 8 byte data field to provide a physical
address, a command and the needed parameters for the
action, as illustrated in the example below.
Data Byte 5
Type #3: two data bytes writing frame with an
Type #4: eight data bytes writing frame with 0x3C
Data2
(<Broad> = ‘0’). If <Broad> = ‘1’, the
physical address of the slave node is provided
by the 7 remaining bits of DATA2. DATA1 will
contain the command code (see Dynamic
assignment of Identifiers), while, if present,
DATA3 to DATA4 will contain the command
parameters, as shown below.
identifier dynamically assigned to a particular
slave node together with an application
command. This type of frame requires that
there are as many dynamically assigned
identifiers as there are AMIS−30621 circuits
using this command connected to the LIN bus.
identifier.
command parameters (e.g. position)
Broad
Data Byte 6
parameters
Data Byte 7
Data Byte 2
Parameters ...
Data3 ...
Data Byte 8