DM330023 Microchip Technology, DM330023 Datasheet - Page 30

BOARD DEV DSPICDEM MCHV

DM330023

Manufacturer Part Number
DM330023
Description
BOARD DEV DSPICDEM MCHV
Manufacturer
Microchip Technology
Series
dsPICDEM™r
Datasheet

Specifications of DM330023

Main Purpose
Power Management, Motor Control
Embedded
Yes, Other
Utilized Ic / Part
dsPIC33F
Primary Attributes
AC Induction (ACIM) Motors, Brushless DC (BLDC) Motors, Permanent Magnet Synchronous (PMSM) Motors
Secondary Attributes
Power Factor Corrected (PFC)
Processor To Be Evaluated
dsPICDEM
Processor Series
dsPIC DSC
Interface Type
RS-232, USB
Operating Supply Voltage
90 V to 265 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DM330023
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
DM330023-2
Manufacturer:
MICROCHIP
Quantity:
12 000
dsPICDEM™ MCHV Development System User’s Guide
DS70605A-page 24
Once code is halted, hovering over a variables opens a tool tip window that contains
the current value of the variable.
2.4.4.2.3
To use a Watch window:
1. The Watch window is made visible on the desktop by selecting View>Watch. It
2. Select an SFR or Symbol from the list and click the related Add button to add it
A Watch window populated with an SFRs and Symbols will look like Figure 2-9. For
more on using Watch windows, see MPLAB IDE Help.
FIGURE 2-9:
2.4.5
When the program is successfully debugged and running, the next step is to program
the device for stand-alone operation in the finished design. When doing this, the
resources reserved for debug are released for use by the application. To program the
application, use the following steps:
1. Disable Starter Kits as a debug tool by selecting Debugger>Select Tool>None.
2. Select Starter Kits as the programmer in the Programmer>Select Programmer
3. Select Programmer>Program.
At this point, the application code will run independently.
Note:
contains four selectable Watch views (via tabs) in which to view variables (SFRs,
symbols and absolute addresses).
to the Watch window. Or click in the “Address” column and enter an absolute
address.
menu.
Programming an Application
This feature must be configured. Select Edit>Properties and click the
Tooltips tab, and select the “Enable Variable Mouseover Values” check
box.
Using Watch Windows
WATCH WINDOW EXAMPLE
 2009 Microchip Technology Inc.

Related parts for DM330023