C8051F800DK Silicon Laboratories Inc, C8051F800DK Datasheet - Page 127

KIT DEV C8051F800

C8051F800DK

Manufacturer Part Number
C8051F800DK
Description
KIT DEV C8051F800
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F800DK

Contents
Board, Cables, CD, Debugger, Power Supply
Processor To Be Evaluated
C8051F800
Data Bus Width
16 bit
Interface Type
USB
Operating Supply Voltage
7 V to 15 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F8xx
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
336-1797
21.5. Comparator0 Reset
Comparator0 can be configured as a reset source by writing a 1 to the C0RSEF flag (RSTSRC.5).
Comparator0 should be enabled and allowed to settle prior to writing to C0RSEF to prevent any turn-on
chatter on the output from generating an unwanted reset. The Comparator0 reset is active-low: if the non-
inverting input voltage (on CP0+) is less than the inverting input voltage (on CP0-), the device is put into
the reset state. After a Comparator0 reset, the C0RSEF flag (RSTSRC.5) will read 1 signifying
Comparator0 as the reset source; otherwise, this bit reads 0. The state of the RST pin is unaffected by this
reset.
21.6. PCA Watchdog Timer Reset
The programmable Watchdog Timer (WDT) function of the Programmable Counter Array (PCA) can be
used to prevent software from running out of control during a system malfunction. The PCA WDT function
can be enabled or disabled by software as described in Section “29.4. Watchdog Timer Mode” on
page 236; the WDT is enabled and clocked by SYSCLK / 12 following any reset. If a system malfunction
prevents user software from updating the WDT, a reset is generated and the WDTRSF bit (RSTSRC.5) is
set to ‘1’. The state of the RST pin is unaffected by this reset.
21.7. Flash Error Reset
If a Flash read/write/erase or program read targets an illegal address, a system reset is generated. This
may occur due to any of the following:
The FERROR bit (RSTSRC.6) is set following a Flash error reset. The state of the RST pin is unaffected by
this reset.
21.8. Software Reset
Software may force a reset by writing a 1 to the SWRSF bit (RSTSRC.4). The SWRSF bit will read 1 fol-
lowing a software forced reset. The state of the RST pin is unaffected by this reset.
A Flash write or erase is attempted above user code space. This occurs when PSWE is set to 1 and a
MOVX write operation targets an address above address 0x3DFF.
A Flash read is attempted above user code space. This occurs when a MOVC operation targets an
address above address 0x3DFF.
A Program read is attempted above user code space. This occurs when user code attempts to branch
to an address above 0x3DFF.
A Flash read, write or erase attempt is restricted due to a Flash security setting (see Section
“19.3. Security Options” on page 114).
Rev. 1.0
C8051F80x-83x
127

Related parts for C8051F800DK