R0E0200F0EMU00 Renesas Electronics America, R0E0200F0EMU00 Datasheet - Page 204

no-image

R0E0200F0EMU00

Manufacturer Part Number
R0E0200F0EMU00
Description
EMULATOR E200 MAIN BODY-SH7780
Manufacturer
Renesas Electronics America
Series
SuperH®r
Type
In-Circuit Emulatorr
Datasheet

Specifications of R0E0200F0EMU00

Contents
Emulator Board, Cables, Software and Documentation
For Use With/related Products
SH7780
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Sequential Setting: In the emulator, sequential setting of an Event Condition is enabled.
Table 5.3 Sequential Event Conditions
178
[CPU
Sequential
Event] Page
Type
2 Channel
Sequential
Many
Channel
Sequential
Event Condition
Ch2 -> 1
Ch4 -> 3
Ch6 -> 5
Ch11 -> 10
Ch3 -> 2 -> 1
Ch4 -> 3-> 2 -> 1
Ch5 -> 4 -> 3-> 2 -> 1 Halts a program after conditions have been matched
Ch6 -> 5 -> 4 -> 3-> 2
-> 1
Ch10 -> 6 -> 5 -> 4 ->
3-> 2 -> 1
Ch11 -> 10 -> 6 -> 5 ->
4 -> 3-> 2 -> 1
Description
Halts a program when after conditions have been
matched in the order of Event Condition 2, 1.
An event condition must be set for Ch2 and Ch1.
Halts a program after conditions have been matched
in the order of Event Condition 4, 3.
An event condition must be set for Ch4 and Ch3.
Halts a program after conditions have been matched
in the order of Event Condition 6, 5.
An event condition must be set for Ch6 and Ch5.
Halts a program after conditions have been matched
in the order of Event Condition 11, 10.
An event condition must be set for Ch11 and Ch10.
Halts a program after conditions have been matched
in the order of Event Condition 3, 2, 1.
An event condition must be set for Ch3, Ch2, and
Ch1.
Halts a program after conditions have been matched
in the order of Event Condition 4, 3, 2, 1.
An event condition must be set for Ch4, Ch3, Ch2,
and Ch1.
in the order of Event Condition 5, 4, 3, 2, 1.
An event condition must be set for Ch5, Ch4, Ch3,
Ch2, and Ch1.
Halts a program after conditions have been matched
in the order of Event Condition 6, 5, 4, 3, 2, 1.
An event condition must be set for Ch6, Ch5, Ch4,
Ch3, Ch2, and Ch1.
Halts a program after conditions have been matched
in the order of Event Condition 10, 6, 5, 4, 3, 2, 1.
An event condition must be set for Ch10, Ch6, Ch5,
Ch4, Ch3, Ch2, and Ch1.
Halts a program after conditions have been matched
in the order of Event Condition 11, 10, 6, 5, 4, 3, 2,
1.
An event condition must be set for Ch11, Ch10,
Ch6, Ch5, Ch4, Ch3, Ch2, and Ch1.