• Specifying the measurement start/end conditions
Notes: 1. When no measurement start/end conditions are specified, measurement is started by
Table 1.3 Conditions Specified in the [Action] Page
Item
PA1
PA2
PA3
PA4
Set the performance measurement conditions in the [Action] page after conditions have been
set in the [Event Condition] dialog box that is opened by double-clicking Ch1 to Ch6 and Ch8
to Ch12 on the [Onchip Event] sheet of the [Event] window.
2.
3.
4.
pa1_start_point
pa1_end_point
pa2_start_point
pa2_end_point
pa3_start_point
pa3_end_point
pa4_start_point
pa4_end_point
executing a program and ended when an event condition is satisfied.
When only the measurement start or end condition is specified, performance cannot be
measured. Be sure to specify both of the measurement start and end conditions.
When the measurement start/end conditions are specified, step operation cannot be
performed. In addition, when execution is restarted from the address where step
operation has been stopped by the break conditions of BREAKPOINT or Event
Condition, step functions are used and operation is disabled. Restart execution after
the settings of the break conditions of BREAKPOINT or Event Condition have been
canceled.
It is not possible to use the break conditions and the start/end conditions for
performance measurement at the same time with one channel. If the start/end
conditions for performance measurement are set, the settings of the break conditions
will be disabled.
Description
Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 1.
Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 1.
Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 2.
Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 2.
Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 3.
Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 3.
Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 4.
Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 4.