[General] page
Note: The system clock (φ) is set as the input for the clock counter setting.
The debugging function in the E6000H emulator is realized by serial communication with the target MCU. The
JTAG clock is used as the input clock in this serial communication. Set the JTAG clock frequency as high as
possible to improve performance in downloading and reading memory. Note that, however, the JTAG clock
frequency must be lower than that of the peripheral modules clock (Pφ) of the target MCU.
16
[Device]
[Mode]
[Clock]
[Clock Mode]
[JTAG Clock]
[Timer Resolution]
[Enable interrupts during step
execution]
[Break on access error]
[Enable read and write on the
fly]
[Enable internal ROM area write]
[User VCC Threshold]
[User Signals]
[Bus Timeout]
[Enable multi break]
[Driver]
[Change driver in start up]
Selects the target MCU to be emulated. See the hardware manual for
details.
Selects the operating mode of the target MCU.
Selects the speed of the input clock of the target MCU. Select one of the
followings:
Emulator Clock (x MHz): Clock signal of the emulator (x: 4, 6, 8, 10, or
12.5)
Target: Clock signal from the user system
Xtal: Crystal oscillator on the evaluation chip board
Sets the operating clock mode of the target MCU.
Sets the JTAG clock frequency.
Selects the resolution of the timer for use in execution time measurement
and performance analysis. Select one of the following values.
Runtime measurement: 52us, 1.6us, or 20ns
Clock counter measurement: CLOCK, CLOCK/2, CLOCK/4, or CLOCK/8
When this box is checked, interrupts are accepted during step execution.
When this box is checked, a break (the user program stops) occurs if
your program accesses a guarded memory area or writes to a write-
protected area.
Selects whether or not to enable an access to memory during user
program execution.
When this box is checked, writing to the on-chip ROM area is enabled.
Sets the voltage level for the user system. [Down] will be displayed in
[User PVcc] of the [Extended Monitor] window when the actual user Vcc
of the target system is lower than the specified value.
When this box is checked, the selected signal from the user system is
enabled.
Select the bus timeout detection time. 100us, 1.6ms, 13ms, or 210ms can
be selected.
When this box is checked, the multibreak function is enabled. This allows
breaking the program for several E6000H emulators at the same time by
using a trigger input and probe pins.
Displays the E6000H driver that is currently installed.
When this box is checked, selection of a driver will be available next time
the emulator is connected.