5.6
5.6.1
• The same hardware resource is used for acquisition of time stamps and the IRQ signals in the trace function.
Table 5.7 Trace Contents
Setting
When [Timestamp] is selected
When [IRQ7-0 all indications] is
selected
• When the user clock (system clock signal φ) has been selected for [Time measurement unit] in the [Trace
5.6.2
• The trace will stop several cycles after a condition is satisfied.
• Six or more bus cycles are required between pass points of sequential trace stop conditions and reset
• Six or more bus cycles are required between the start and end of measurement when [1-2], [3-4], or [5-6] is
• Fifteen or more bus cycles are required between the start and end of measurement when [7-8] is specified in
• Six or more bus cycles are required from the start of execution to satisfaction of a trace stop mode condition.
• A sequential break or a trace stop may be incorrect when the user program is executed after the specified
• The Point to Point trace mode is not available when channel 1 is used for the performance analysis function.
5.6.3
• When the range for searching is specified in the [General] page, a PTR value to end the search can be
• When the user clock (i.e. system clock signal φ) has been selected in [Time measurement unit] of the [Trace
5.6.4
• After the trace information is filtered, all trace information displayed in the [Trace] window is saved; a range
• When the user clock (i.e. system clock signal φ) has been selected in [Time measurement unit] of the [Trace
Accordingly, the trace contents differ depending on the [Selection of the trace contents] setting in the [Trace
Acquisition Properties] dialog box.
acquisition] dialog box, the time stamp is displayed for 32 bits in hexadecimal.
condition.
specified in [Run time count between trigger outputs] of the [Trace Acquisition Properties] dialog box.
[Run time count between trigger outputs] of the [Trace Acquisition Properties] dialog box.
address condition has been applied as the PC address to start execution.
specified in the [Start PTR] option, and a PTR value to start the search can be specified in the [End PTR].
Acquisition Properties] dialog box, no time stamp information will be searched.
for saving trace information cannot be specified. To save a specific range of trace information, the filter
range must be specified in the [General] page of the [Trace Filter] dialog box.
Acquisition Properties] dialog box, no time stamp information will be filtered.
Displaying the Trace Information
Searching for a Trace Record
Trace Functions
Specifying Trace Acquisition Conditions
Filtering Trace Records
Description
Acquires and displays timestamp in 32 bits. The IRQ signals
are not acquired.
Acquires and displays the IRQ signals. The time stamp is
displayed with the lower 16 bits fixed to 0.