HD6417708SF60V Renesas Electronics America, HD6417708SF60V Datasheet - Page 373

IC SUPERH MPU ROMLESS 208LQFP

HD6417708SF60V

Manufacturer Part Number
HD6417708SF60V
Description
IC SUPERH MPU ROMLESS 208LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417708SF60V

Core Processor
SH-2
Core Size
32-Bit
Speed
60MHz
Connectivity
EBI/EMI, SCI, SmartCard
Peripherals
POR, WDT
Number Of I /o
8
Program Memory Type
ROMless
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
208-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Ram Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417708SF60V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit 4—Framing Error (FER): Indicates that data reception aborted due to a framing error in
asynchronous mode.
Bit 4: FER
0
1
Bit 3—Parity Error (PER): Indicates that data reception (with parity) aborted due to a parity error
in asynchronous mode.
Bit 3: PER
0
1
Description
Receiving is in progress or has ended normally.
Clearing the RE bit to 0 in the serial control register does not affect the FER bit,
which retains its previous value.
FER is cleared to 0 when the chip is reset or enters standby mode or software
reads FER after it has been set to 1, then writes 0 in FER.
A receive framing error occurred.
When the stop bit length is two bits, only the first bit is checked. The second stop
bit is not checked. When a framing error occurs, the SCI transfers the receive
data into SCRDR but does not set RDRF. Serial receiving cannot continue while
FER is set to 1. In synchronous mode, serial transmitting is also disabled.
FER is set to 1 if the stop bit at the end of receive data is checked and found to
be 0.
Description
Receiving is in progress or has ended normally.
Clearing the RE bit to 0 in the serial control register does not affect the PER bit,
which retains its previous value.
PER is cleared to 0 when the chip is reset or enters standby mode or software
reads PER after it has been set to 1, then writes 0 in PER.
A receive parity error occurred.
When a parity error occurs, the SCI transfers the receive data into SCRDR but
does not set RDRF. Serial receiving cannot continue while PER is set to 1. In
synchronous mode, serial transmitting is also disabled.
PER is set to 1 if the number of 1s in receive data, including the parity bit, does
not match the even or odd parity setting of the parity mode bit (O/E) in the serial
mode register (SCSMR).
(Initial value)
(Initial value)
353