ST7FLITEU05M6 STMicroelectronics, ST7FLITEU05M6 Datasheet - Page 32

MCU 8BIT SGL VOLT FLASH SO-8

ST7FLITEU05M6

Manufacturer Part Number
ST7FLITEU05M6
Description
MCU 8BIT SGL VOLT FLASH SO-8
Manufacturer
STMicroelectronics
Series
ST7r
Datasheet

Specifications of ST7FLITEU05M6

Core Processor
ST7
Core Size
8-Bit
Speed
8MHz
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
5
Program Memory Size
2KB (2K x 8)
Program Memory Type
FLASH
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
2.4 V ~ 5.5 V
Data Converters
A/D 5x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
8-SOIC (3.9mm Width)
Processor Series
ST7FLITEUx
Core
ST7
Data Bus Width
8 bit
Data Ram Size
128 B
Interface Type
ICC
Maximum Clock Frequency
4 MHz
Number Of Programmable I/os
5
Number Of Timers
2
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Development Tools By Supplier
ST7FUS-PRIMER, ST7FLITE-SK/RAIS, ST7FLITU0-D/RAIS, STX-RLINK
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 5 Channel
For Use With
497-5858 - EVAL BOARD PLAYBACK ST7FLITE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Connectivity
-
Lead Free Status / Rohs Status
 Details
Supply, reset and clock management
7
7.1
7.2
32/139
Supply, reset and clock management
The device includes a range of utility features for securing the application in critical
situations (for example in case of a power brown-out), and reducing the number of external
components.
Main features
Internal RC oscillator adjustment
The ST7 contains an internal RC oscillator with a specific accuracy for a given device,
temperature and voltage. It can be selected as the start up clock through the CKSEL[1:0]
option bits (see
required in the application. This is done by software writing a 10-bit calibration value in the
RCCR (RC Control Register) and in the bits [6:5] in the SICSR (SI control status register).
Whenever the microcontroller is reset, the RCCR returns to its default value (FFh), i.e. each
time the device is reset, the calibration value must be loaded in the RCCR. Predefined
calibration values are stored in Flash memory for 3.3 and 5 V V
as shown in the following table.
Table 5.
1. DEE0h, DEE1h, DEE2h and DEE3h are located in a reserved area but are special bytes containing also
the RC calibration values which are read-accessible only in user mode. If all the Flash space (including the
RC calibration value locations) has been erased (after the readout protection removal), then the RC
calibration values can still be obtained through these two addresses.
Clock management
Reset sequence manager (RSM)
System integrity management (SI)
RCCRH0
RCCRH1
RCCRL0
RCCRL1
RCCR
8 MHz internal RC oscillator (enabled by option byte)
External clock input (enabled by option byte)
Main supply low voltage detection (LVD) with reset generation (enabled by option
byte)
Auxiliary voltage detector (AVD) with interrupt capability for monitoring the main
supply
Predefined RC oscillator calibration values
Section 15.1 on page
f
f
Conditions
V
RC
RC
V
T
T
DD
A
A
DD
= 25 °C
= 25 °C
= 8 MHz
= 8 MHz
= 3.3 V
= 5 V
127). It must be calibrated to obtain the frequency
ST7LITEU05/ST7LITEU09 address
DEE0h
DEE1h
DEE2h
DEE3h
DD
ST7LITEU05 ST7LITEU09
(1)
(1)
(1)
(1)
supply voltages at 25 °C,
(CR[9:2] bits)
(CR[1:0] bits)
(CR[9:2] bits)
(CR[1:0] bits)

Related parts for ST7FLITEU05M6