CLRC63201T/0FE,112 NXP Semiconductors, CLRC63201T/0FE,112 Datasheet - Page 79

IC I.CODE HS READER 32-SOIC

CLRC63201T/0FE,112

Manufacturer Part Number
CLRC63201T/0FE,112
Description
IC I.CODE HS READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
I-Coder
Datasheets

Specifications of CLRC63201T/0FE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO14443-A, ISO14443-B, ISO15693, ISO18000-3
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-2199-5
935269690112
CLRC632
CLRC63201TD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CLRC63201T/0FE,112
Manufacturer:
IR
Quantity:
3 400
Part Number:
CLRC63201T/0FE,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
CLRC632_35
Product data sheet
PUBLIC
11.2.1.1 Using the Transmit command
11.2.1 Transmit command 1Ah
11.2 Commands for ISO/IEC 14443 A card communication
The CLRC632 is a fully ISO/IEC 14443 A, ISO/IEC 14443 B, ISO/IEC 15693 and
I-CODE1 compliant reader IC. This enables the command set to be more flexible and
generalized when compared to dedicated MIFARE or I-CODE1 reader ICs.
to
and related communication protocols.
Table 136. Transmit command 1Ah
The Transmit command reads data from the FIFO buffer and sends it to the transmitter. It
does not return any data. The Transmit command can only be started by the
microprocessor.
To transmit data, one of the following sequences can be used:
When the transmitter requests the next data byte to ensure the data stream on the RF
interface is continuous and the FIFO buffer is empty, the Transmit command automatically
terminates. This causes the internal state machine to change its state from transmit to
idle.
When the data transmission to the card is finished, the TxIRq flag is set by the CLRC632
to indicate to the microprocessor transmission is complete.
Remark: If the microprocessor overwrites the transmit code in the Command register
with another command, transmission stops immediately on the next clock cycle. This can
produce output signals that are not in accordance with ISO/IEC 14443 A.
Command
Transmit
1. All data to be transmitted to the card is written to the FIFO buffer while the Idle
2. The command code for the Transmit command is stored in the Command register.
3. Part of the data transmitted to the card is written to the FIFO buffer while the Idle
Section 11.2.5
command is active. Then the command code for the Transmit command is written to
the Command register.
Remark: This is possible for transmission of a data stream up to 64 bytes.
Since there is not any data available in the FIFO buffer, the command is only enabled
but transmission is not activated. Data transmission starts when the first data byte is
written to the FIFO buffer. To generate a continuous data stream on the RF interface,
the microprocessor must write the subsequent data bytes into the FIFO buffer in time.
Remark: This allows transmission of any data stream length but it requires data to be
written to the FIFO buffer in time.
command is active. Then the command code for the Transmit command is written to
the Command register. While the Transmit command is active, the microprocessor
can send further data to the FIFO buffer. This is then appended by the transmitter to
the transmitted data stream.
Remark: This allows transmission of any data stream length but it requires data to be
written to the FIFO buffer in time.
Value
1Ah
describe the command set for ISO/IEC 14443 A card communication
Rev. 3.5 — 10 November 2009
Action
transmits data from FIFO buffer to card
Multiple protocol contactless reader IC (MIFARE/I-CODE1)
073935
Arguments
and data
data stream
CLRC632
© NXP B.V. 2009. All rights reserved.
Section 11.2.1
Returned
data
-
79 of 126

Related parts for CLRC63201T/0FE,112