MCP4441T-503E/ST Microchip Technology, MCP4441T-503E/ST Datasheet - Page 63

IC DGTL POT 129TAPS QUAD 20TSSOP

MCP4441T-503E/ST

Manufacturer Part Number
MCP4441T-503E/ST
Description
IC DGTL POT 129TAPS QUAD 20TSSOP
Manufacturer
Microchip Technology
Datasheet

Specifications of MCP4441T-503E/ST

Package / Case
20-TSSOP (0.173", 4.40mm Width)
Temperature Coefficient
150 ppm/°C Typical
Taps
129
Resistance (ohms)
50K
Number Of Circuits
4
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Number Of Pots
Quad
Taps Per Pot
129
Resistance
50 KOhms
Wiper Memory
Non Volatile
Buffered Wiper
Buffered
Digital Interface
I2C
Operating Supply Voltage
2.7 V to 5.5 V
Supply Current
600 uA
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Description/function
Quad I2C Digital POT with Nonvolatile Memory
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP4441T-503E/ST
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
7.2
Only the Read Command and the Write Command
have Data Byte(s).
The Write command concatenates the 8 bits of the
Data Byte with the one data bit (D8) contained in the
Command Byte to form 9 bits of data (D8:D0). The
Command Byte format supports up to 9 bits of data so
that the 8-bit resistor network can be set to Full-Scale
(100h or greater). This allows wiper connections to
Terminal A and to Terminal B. The D9 bit is currently
unused.
TABLE 7-3:
© 2010 Microchip Technology Inc.
Write Data
Read Data
Increment Wiper
Decrement Wiper
High Voltage
High Voltage
High Voltage
High Voltage
Modify Write Protect or WiperLock
Technology (High Voltage)
Modify Write Protect or WiperLock
Technology (High Voltage)
Note 1:
2:
3:
Data Byte
Command Name
This command will only complete, if wiper is “unlocked” (WiperLock Technology is Disabled).
If the command is executed using address 02h, 03h 08h, or 09h; that corresponding wiper is locked or
if with address 0Fh, then Write Protect is enabled.
If the command is executed using with address 02h, 03h 08h, or 09h; that corresponding wiper is unlocked
or if with address 0Fh, then Write Protect is disabled.
Write Data
Read Data
Increment Wiper
Decrement Wiper
COMMANDS
- Enable
- Disable
EEPROM
Value in
Writes
Yes
Yes
(1)
(2)
(3)
Operates on Volatile/
Nonvolatile memory
Nonvolatile Only
Nonvolatile Only
Volatile Only
Volatile Only
Volatile Only
Volatile Only
Both
Both
Both
Both
7.3
If the four address bits received (AD3:AD0) and the two
command
combination, the MCP44XX will Acknowledge the I
bus.
If the address bits and command bits are an invalid
combination, then the MCP44XX will Not Acknowledge
the I
Once an error condition has occurred, any following
commands are ignored until the I
Start Condition.
7.3.1
A Restart or Stop condition in the expected data bit
position will abort the current command sequence and
data will not be written to the MCP44XX.
2
C bus.
(2)
(3)
Error Condition
ABORTING A TRANSMISSION
bits
HVC pin?
(V
MCP444X/446X
Voltage
High
IHH
Yes
Yes
Yes
Yes
Yes
Yes
received
) on
unprotected
WiperLock or
Write Protect
protected
unlocked
unlocked
unlocked
unlocked
unchanged
unchanged
unchanged
unchanged
Impact on
unlocked/
(C1:C0)
locked/
2
C bus is reset with a
DS22265A-page 63
(1)
(1)
(1)
(1)
(2)
(3)
are
“locked”?
Wiper is
Works
when
a
Yes
Yes
Yes
No
No
No
No
No
No
No
valid
2
C

Related parts for MCP4441T-503E/ST