KIT33912G5DGEVME Freescale Semiconductor, KIT33912G5DGEVME Datasheet - Page 57

Power Management Modules & Development Tools 33912G5 LIN SBC KIT

KIT33912G5DGEVME

Manufacturer Part Number
KIT33912G5DGEVME
Description
Power Management Modules & Development Tools 33912G5 LIN SBC KIT
Manufacturer
Freescale Semiconductor
Type
Motor / Motion Controllers & Driversr
Datasheets

Specifications of KIT33912G5DGEVME

Interface Type
SPI
Product
Power Management Modules
Silicon Manufacturer
Freescale
Silicon Core Number
MC33912
Kit Application Type
Interface
Application Sub Type
LIN System
Kit Contents
Board, CD, Misc Cable
Rohs Compliant
Yes
For Use With/related Products
MC33912
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 35. Static Electrical Characteristics (continued)
34912, unless otherwise noted. Typical values noted reflect the approximate parameter mean at T
conditions, unless otherwise noted.
Analog Integrated Circuit Device Data
Freescale Semiconductor
HIGH SIDE OUTPUTS HS1 AND HS2 PINS (HS1, HS2)
LOW SIDE OUTPUTS LS1 AND LS2 PINS (LS1, LS2)
100.
101.
102.
103.
104.
105.
106.
107.
Output Drain-to-Source On Resistance
Output Current Limitation
Open Load Current Detection
Leakage Current
Short-circuit Detection Threshold
Over-temperature Shutdown
Over-temperature Shutdown Hysteresis
Output Drain-to-Source On Resistance
Output Current Limitation
Open Load Current Detection
Leakage Current
Active Output Energy Clamp
Short-circuit Detection Threshold
Over-temperature Shutdown
Over-temperature Shutdown Hysteresis
Notes
98.
99.
Characteristics noted under conditions 5.5 V ≤ V
T
T
T
0 V < V
-0.2 V < V
5.5 V < V
T
T
T
2.0 V < V
-0.2 V < V
I
5.5 V < V
OUT
J
J
J
J
J
J
= 25°C, I
= 150°C, I
= 150°C, I
= 25°C, I
= 125°C, I
= 125°C, I
This parameter is production tested up to T
When over-current occurs, the corresponding high side stays ON with limited current capability and the HSxCL flag is set in the HSSR
When open load occurs, the flag (HSxOP) is set in the HSSR
When short-circuit occurs and if HVSE flag is enabled, both HS automatic shutdown.
When over-temperature shutdown occurs, both high sides are turned off. All flags in HSSR are set.
When over-current occurs, the corresponding low side stays ON with limited current capability and the LSxCL flag is set in the LSSR
When open load occurs, the flag (LSxOP) is set in the LSSR.
When short-circuit occurs and if HVSE Flag is enabled, both LS automatic shutdown
When over-temperature shutdown occurs, both low sides are turned off. All flags in LSSR are set.
Guaranteed by characterization but not production tested
= 150 mA
OUT
SUP
OUT
SUP
HSX
OUT
LOAD
LOAD
< V
LOAD
LOAD
LOAD
LOAD
< 27 V
< V
< 27 V
< V
< VS1
SUP
= 50 mA; V
= 150 mA, V
SUP
S2
= 50 mA; V
= 30 mA; 5.5 V < V
= 150 mA, V
= 120 mA, 5.5 V < V
- 2.0 V
+ 0.2 V
(99)
(103)
(102),
(106),
Characteristic
(100)
(104)
SUP
SUP
(101)
SUP
(105)
(107)
(107)
SUP
> 9.0 V
> 9.0 V
> 9.0 V
> 9.0 V
(107)
(107)
SUP
SUP
(98)
< 9.0 V
< 9.0 V
A
= 125°C and guaranteed by process monitoring up to T
(98)
SUP
≤ 18 V, -40°C ≤ T
.
T
T
A
Symbol
R
HSSD_HYS
R
LSSD_HYS
V
I
I
I
V
T
I
V
LIMHSX
T
LIMLSX
OLHSX
I
OLLSX
I
DS(ON)
DS(ON)
CLAMP
≤ 125°C for the 33912 and -40°C ≤ T
LEAK
LEAK
THSC
HSSD
THSC
LSSD
V
V
SUP
STATIC ELECTRICAL CHARACTERISTICS
SUP
Min
150
160
150
2.0
60
+2.0
-2.0
ELECTRICAL CHARACTERISTICS
J
= 150°C.
A
Typ
120
165
275
165
= 25°C under nominal
5.0
8.0
10
10
V
SUP
A
Max
250
180
350
180
7.0
7.5
2.5
4.5
10
14
10
10
12
10
≤ 85°C for the
+5.0
Unit
mA
mA
mA
mA
33912
µA
µA
°C
°C
°C
°C
Ω
V
Ω
V
V
57
.
.

Related parts for KIT33912G5DGEVME