CV500ETN01 Omron, CV500ETN01 Datasheet - Page 195

no-image

CV500ETN01

Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Command/Response Reference
Command Block
Response Block
Results Storage Format
Parameters
Socket Option (Command)
UDP Socket Number
(Command)
Results Storage Area
(Command)
Destination IP Address
(Command)
Destination UDP Port
Number (Command)
Number of Bytes Sent
(Command, Results
Storage Area)
Send Data (Command)
Response Codes
170
Command
27 03
code
Socket option
UDP socket number
Results storage area
The socket option specified as 1 byte. The setting is not valid for this com-
mand. Set to 0.
The UDP socket number to send the data specified as 1 byte between 1 and
8.
The area in which the result of the command execution is stored. The first byte
specifies the memory area and data type (variable type). The 2nd to 4th bytes
specify the beginning address of the results storage area. Refer to page 158
for details about the variable types and addresses that can be specified.
The IP address of the node to which data is being sent is specified in hexa-
decimal.
The UDP port number of the node to which data is being sent.
The number of bytes in the data sent by this command. Up to 1,984 bytes can
be specified, or up to 1,472 bytes can be specified if the broadcast address is
specified as the send destination. The results storage area stores the actual
number of bytes sent.
Specifies the data sent to the remote node.
0000
0105
0302
1001
1002
1003
Command
Response
27 03
Response code
code
code
Response
Number of
bytes sent
code
Destination IP address
Normal
Local IP address setting error
CPU Unit error; execution not possible.
Command too large
Command too small
The number of bytes sent does not match the sent data
length.
port number
Destination
UDP
Number of
bytes sent
Description
1984 bytes max.
Send data
Section 7-3