CV500ETN01 Omron, CV500ETN01 Datasheet - Page 92

no-image

CV500ETN01

Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3-4
SMTP Server Setup
SMTP
SMTP
For details, refer to SECTION 2 Mail Send Function in the Operation Manual
Construction of Applications.
Server specifi-
cation type
IP Address
Host name
Port No.
Local mail
address
Use POP before
SMTP
Item
Select whether the SMTP server used for send-
ing mail is to be specified by IP address or the
host's domain name (i.e., host name).
Set the IP address for the SMTP server used for
sending mail.
This setting is enabled only when “IP address” is
selected as the method for specifying the server.
Set the host domain name (i.e., the host name)
for the SMTP server that is to be used for send-
ing mail.
This setting is enabled only when “host name” is
selected as the method for specifying the server.
Set the port to be used for connecting to the
SMTP server that is to be used for sending mail.
This setting does not normally need to be
changed.
Set the mail address for the Ethernet Unit.
Select whether or not to use the mail receiving
method (POP before SMTP) in which the POP
server must be accessed (to receive mail) before
the SMTP server is accessed (to send mail).
Contents
IP Address
0.0.0.0
None
0
(No. 25 is used.)
None
Not checked
Section 3-4
Default
67