Overview of Startup Procedure
2-1
30
Note 1: Used mainly when a Programming Console is used to set only the local IP address (set in allocated DM words). When using this method, always
Use the default IP address.
Turn ON power to the CPU Unit.
2: The local IP address and other parameters can be set with the CX-Programmer.
3: A PLC Programming Device is required: CX-Programmer, CX-Integrator, Programming Console, etc.
4: The CX-Integrator is required.
5: The CX-Programmer is required.
and address conversion method.
Connecting to the Ethernet Unit
without making any settings.
Determine the local IP address
leave the local IP address in the CPU Bus Unit Setup Area set to the default value of 0.0.0.0 If the CPU Bus Unit Setup Area contains any other
value, any setting made in the allocated DM words will be overwritten with it.
Create the routing tables.
Mount the Unit to the PLC.
(Create IP router tables.)
(PING command and/or
using twisted-pair cable.
Connect to the network
Check communications.
Set the node number.
Perform Unit setup.
Set the unit number.
Create the I/O tables.
Overview of Startup Procedure
echo test).
Refer to IP Address in 2-9 Basic Settings.
(See note 3.)
(See note 4.)
(See note 5.)
Refer to 6-4 Creating Routing
Tables.
Refer to SECTION 3 CX-Programmer Unit Setup.
Refer to IP Address in 2-9 Basic Settings.
Refer to 2-10 Unit Setup for Particular Applications.
Refer to SECTION 5 Determining IP Addresses.
Refer to 2-2 Switch Settings.
Refer to 2-2 Switch Settings.
Refer to 2-3 Mounting to a PLC.
Refer to 2-4 Network Installation.
Refer to 2-6 Creating I/O Tables.
The following procedure is the same for the CS Series and CJ Series.
Set local IP address in DM Area
words allocated for CPU Unit Units.
Setting only the IP address (not
making other Unit settings) for
simple application or operating
with only the Programming
Console (setting possible with CX-
Programmer or Programming
Console).
Refer to IP Address in
Refer to 4-2 DM Area Allocations.
(See note 1.)
Routing tables must be set to enable the following.
Using the FINS communications service
Using the CMND instruction with more than one
Communications Unit mounted to the PLC.
2-9 Basic Settings
Setting system settings freely
(setting possible with
CX-Programmer or Web function).
Set the local IP address in the
CPU Bus Unit setup area.
.
(See note 2.)
Section 2-1
Refer to IP
Address in 2-9
Basic Settings.