QO112M100 SQUARE D, QO112M100 Datasheet - Page 21

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Single-Phase, Three-Wire, 120/240 Vac; Main Circuit Breaker Ind oor
1
2
3
A UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) with factory-installed service disconnect.
B UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) with field installed main lugs when not more than six disconnecting
03/2007
Convertible Mains – Factory-Installed Main Circuit Breaker
QOM1 Main Frame Size – Convertible to Main Lugs or Lower Amperage Main Circuit Breaker – Copper Bus
Convertible Mains – Factory-Installed Main Circuit Breaker
QOM2 Main Frame Size – Convertible to Main Lugs or Lower Amperage Main Circuit Breaker – Copper Bus
Fixed Mains – Factory-Installed Main Circuit Breaker
Rating in
Mains
Amps
Short circuit current rating depends on lowest AIR rating of main or branch circuit breaker installed.
22,000 A rms symmetrical maximum when supplied by integral type QOM-VH main circuit breaker from Square D
interrupting rating and when all installed QO
maximum when main lugs kits are installed.
UL Listed for 5000 A rms symmetrical short circuit current rating when used in 3-phase, 240 Vac, corner grounded Delta systems. Use 240 Vac circuit breakers only.
means are provided and when not used as a lighting and appliance branch circuit panelboard. See NEC Article for Lighting and Appliance Branch Circuit Panelboard.
100
125
150
200
225
300
400
QO112M100
QO116M100
QO120M100
QO124M100
QO132M100
QO124M125
QO132M125
QO12030M150
QO124M150
QO130M150
QO132M150
QO12040M200
QO124M200
QO130M200
QO13040M200
QO140M200
QO142M200
QO140M225
QO142M225
QON42MS300
MH68 (Enclosure)
QON42MS400
MH68 (Enclosure)
Catalog Number
Load Center
QOC12UF/S
QOC20U100F/S
QOC20U100F/S
QOC24UF/S
QOC32UF
QOC24UF/S
QOC32UF
QOC30UF/S
QOC30UF/S
QOC30UF/S
QOC40UF/S
QOC30UF/S
QOC30UF/S
QOC30UF/S
QOC30UF/S
QOC40UF/S
QOC42UF/S
QOC42UF/S
QOC42UF/S
MHC68VF/S
MHC68VF/S
Cover Catalog
Load Center
Number
®
branch circuit breakers have 10,0000 A rms symmetrical minimum interrupting rating. 65,000 A rms symmetrical
(See Notes)
Equipment
UL Listed
Service
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A, B
A
A
QO
®
Maximum
UL Short
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
42,000 A
42,000 A
Rating
Circuit
and Homeline
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
Main Wire Size
AWG/kcmil
(1)#4 500
(1)#4 600
(2)#4 250
(2)#4 3 /0
#4 250
#4 250
#4 250
#4 250
#4 250
#4 250
#4 250
#4 250
#4 250
#4 250
#4 300
#4 300
Al/Cu
#4 2/0
#4 2/0
#4 1
#4 1
#4 1
#4 1
#4 1
© 2007 Schneider Electric All Rights Reserved
®
Load Centers and Enclosures
Enclosure
®
(Page 26)
with 22,000 A rms symmetrical minimum
No.
10
10
11
11
11
16
16
5
6
6
7
8
7
8
9
9
9
9
9
9
9
Technical Information
or Bottom
Position
Mains
Top
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Delta Systems
UL Listed for
Grounded
Corner
Yes
Yes
No
No
No
No
No
21

Related parts for QO112M100