QO112M100 SQUARE D, QO112M100 Datasheet - Page 46

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Homeline
General Information and Application Data
46
© 2007 Schneider Electric All Rights Reserved
HOMFP
RB Hub
®
HOM Surgebreaker
2 spaces required.
Circuit Breakers and Load Centers—Class 1170
Surge Arrester
LK100AN
QOM2FP
PK15GTA
BC200 Enclosure Coupling
QOM1FP
®
Accessories
Bolt-On Hubs
Equipment with an RB suffix, meaning Rainproof NEMA Type 3R
construction, uses the bolt-on hubs listed below. RB de vices will accept
0.75 in (19 mm) through 2.50 in (64 mm) bolt-on hubs without the use of
reducers.
Off-center conduit thread openings and elongated mounting holes provide
quick and easy adjustment to eliminate costly conduit offsets and bends.
Hubs are suitable for use with conduit having ANSI standard taper pipe
thread.
UL Listed Bolt-On Hubs for RB Devices
UL Listed Enclosure Coupling for RB Devices
Surgebreaker
Grounding Bar Kits
Available with #1 4/0 AWG lug PK15GTA-L, PK18GTA-L and PK23GTA-L
(see Technical Information on page 48)
Auxiliary Neutral Lugs
Cover Filler Plates
NOTE: Closing cap (catalog number B-CAP) is provided factory-installed on each device having
the RB suffix.
Conduit Size
Hub Cat. No.
Cat. No.
HOM2175SB UL Listed secondary surge arrester
Easy plug-on installation for Homeline
LED indicates operational status
Plug-on design requires two pole spaces
Designed to protect electrical service and major household appliances ,
excluding electronic devices
Field installable in all load centers
Wire size of terminals (see Technical Information on page 48)
Suitable for copper or aluminum wire
UL Listed for copper or aluminum wire
Field installable on neutral assembly
Fast to install; snap-in type
HOMFP branch circuit
QOM1FP 50 1 25 A main circuit breaker
QOM2FP 150 225 A main circuit breaker
BC200
LK70AN: #12 2 Al or #14 4 Cu AWG
LK100AN: #6 2/0 Al/Cu AWG
LK125AN: #14 2/0 Al/Cu AWG
Designed for connecting wireway or other enclosures to units having RB
bolt-on conduit provisions. Provides a bushed opening equal to 2 in conduit.
Eliminates the need for conduit nippling.
®
Secondary Surge Arrester
0.75 in
9 mm
B075
1.00 in
25 mm
B100
1.25 in
32 mm
B125
®
load center
1.50 in
38 mm
B150
2.00 in
51 mm
B200
2.50 in
64 mm
03/2007
B250