M29DW128G70NF6E

Manufacturer Part NumberM29DW128G70NF6E
DescriptionP7ED TSOP56 DUAL BANK
ManufacturerNUMONYX
M29DW128G70NF6E datasheet
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
Page 41
42
Page 42
43
Page 43
44
Page 44
45
Page 45
46
Page 46
47
Page 47
48
Page 48
49
Page 49
50
Page 50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
Page 47/85

Download datasheet (2Mb)Embed
PrevNext
M29DW128G
before other commands are issued. The error bit is output on DQ5 when the status register
is read.
Note that the Program command cannot change a bit set to ’0’ back to ’1’ and attempting to
do so will set DQ5 to ‘1’. A bus read operation to that address will show the bit is still ‘0’. One
of the erase commands must be used to set all the bits in a block or in the whole memory
from ’0’ to ’1’.
8.2.4
Erase timer bit (DQ3)
The erase timer bit can be used to identify the start of program/erase controller operation
during a Block Erase command. Once the program/erase controller starts erasing the erase
timer bit is set to ’1’. Before the program/erase controller starts the erase timer bit is set to ’0’
and additional blocks to be erased may be written to the command interface. The erase
timer bit is output on DQ3 when the status register is read.
8.2.5
Alternative toggle bit (DQ2)
The alternative toggle bit can be used to monitor the program/erase controller during erase
operations. The alternative toggle bit is output on DQ2 when the status register is read.
During chip erase and block erase operations the toggle bit changes from ’0’ to ’1’ to ’0’,
etc., with successive bus read operations from addresses within the blocks being erased. A
protected block is treated the same as a block not being erased. Once the operation
completes the memory returns to read mode.
During erase suspend the alternative toggle bit changes from ’0’ to ’1’ to ’0’, etc. with
successive bus read operations from addresses within the blocks being erased. Bus read
operations to addresses within blocks not being erased will output the memory array data as
if in read mode.
After an erase operation that causes the error bit to be set, the alternative toggle bit can be
used to identify which block or blocks have caused the error. The alternative toggle bit
changes from ’0’ to ’1’ to ’0’, etc. with successive bus read operations from addresses within
blocks that have not erased correctly. The alternative toggle bit does not change if the
addressed block has erased correctly.
8.3
Buffered program abort bit (DQ1)
The Buffered program abort bit, DQ1, is set to ‘1’ when a write to buffer program or
enhanced buffered program operation aborts. The Buffered Program Abort and Reset
command must be issued to return the device to read mode (see write to buffer program in
Section 7.1: Standard
commands).
Registers
47/85