P80C31SBPN NXP Semiconductors, P80C31SBPN Datasheet - Page 14

MCU 8-Bit 80C 80C51 CISC ROMLess 3.3V/5V 40-Pin PDIP Tube

P80C31SBPN

Manufacturer Part Number
P80C31SBPN
Description
MCU 8-Bit 80C 80C51 CISC ROMLess 3.3V/5V 40-Pin PDIP Tube
Manufacturer
NXP Semiconductors
Datasheets

Specifications of P80C31SBPN

Package
40PDIP
Device Core
80C51
Family Name
80C
Maximum Speed
16 MHz
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
32
Interface Type
UART
Number Of Timers
3
Ram Size
128 Byte
Program Memory Type
ROMLess
Operating Temperature
0 to 70 °C
Controller Family/series
80C51
No. Of I/o's
32
Ram Memory Size
128Byte
Cpu Speed
16MHz
No. Of Timers
3
Digital Ic Case Style
DIP
Supply Voltage Range
2.7V To 5.5V
Core Size
8 Bit
Embedded Interface Type
UART
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P80C31SBPN
Manufacturer:
TDK-EPCOS
Quantity:
30 000
Part Number:
P80C31SBPN
Manufacturer:
PHILIPS
Quantity:
6
Part Number:
P80C31SBPN
Manufacturer:
NXP
Quantity:
1 079
Part Number:
P80C31SBPN
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
P80C31SBPN
Quantity:
54
Part Number:
P80C31SBPNЈ¬112
Manufacturer:
NXP
Quantity:
7 020
1. Capture/reload occurs only on timer/counter overflow.
2. Capture/reload occurs on timer/counter overflow and a 1-to-0 transition on T2EX (P1.1) pin except when Timer 2 is used in the baud rate
Philips Semiconductors
Table 5. Timer 2 as a Timer
Table 6. Timer 2 as a Counter
NOTES:
Enhanced UART
The UART operates in all of the usual modes that are described in
the first section of Data Handbook IC20, 80C51-Based 8-Bit
Microcontrollers . In addition the UART can perform framing error
detect by looking for missing stop bits, and automatic address
recognition. The 80C31/32 UART also fully supports multiprocessor
communication.
When used for framing error detect the UART looks for missing stop
bits in the communication. A missing bit will set the FE bit in the
SCON register. The FE bit shares the SCON.7 bit with SM0 and the
function of SCON.7 is determined by PCON.6 (SMOD0) (see
Figure 7). If SMOD0 is set then SCON.7 functions as FE. SCON.7
functions as SM0 when SMOD0 is cleared. When used as FE
SCON.7 can only be cleared by software. Refer to Figure 8.
Automatic Address Recognition
Automatic Address Recognition is a feature which allows the UART
to recognize certain addresses in the serial bit stream by using
hardware to make the comparisons. This feature saves a great deal
of software overhead by eliminating the need for the software to
examine every serial address which passes by the serial port. This
feature is enabled by setting the SM2 bit in SCON. In the 9 bit UART
modes, mode 2 and mode 3, the Receive Interrupt flag (RI) will be
automatically set when the received byte contains either the “Given”
address or the “Broadcast” address. The 9 bit mode requires that
the 9th information bit is a 1 to indicate that the received information
is an address and not data. Automatic address recognition is shown
in Figure 9.
The 8 bit mode is called Mode 1. In this mode the RI flag will be set
if SM2 is enabled and the information received has a valid stop bit
following the 8 address bits and the information is either a Given or
Broadcast address.
Mode 0 is the Shift Register mode and SM2 is ignored.
Using the Automatic Address Recognition feature allows a master to
selectively communicate with one or more slaves by invoking the
Given slave address or addresses. All of the slaves may be
contacted by using the Broadcast address. Two special Function
Registers are used to define the slave’s address, SADDR, and the
address mask, SADEN. SADEN is used to define which bits in the
2000 Aug 07
80C51 8-bit microcontroller family
128/256 byte RAM ROMless low voltage (2.7V–5.5V),
low power, high speed (33 MHz)
16-bit Auto-Reload
16-bit Capture
Baud rate generator receive and transmit same baud rate
Receive only
Transmit only
16-bit
Auto-Reload
generator mode.
MODE
MODE
MODE
MODE
INTERNAL CONTROL (Note 1)
INTERNAL CONTROL (Note 1)
14
uniquely addressed by 1110 0110. Slave 1 requires that bit 1 = 0 and
SADDR are to b used and which bits are “don’t care”. The SADEN
mask can be logically ANDed with the SADDR to create the “Given”
address which the master will use for addressing each of the slaves.
Use of the Given address allows multiple slaves to be recognized
while excluding others. The following examples will help to show the
versatility of this scheme:
Slave 0
Slave 1
In the above example SADDR is the same and the SADEN data is
used to differentiate between the two slaves. Slave 0 requires a 0 in
bit 0 and it ignores bit 1. Slave 1 requires a 0 in bit 1 and bit 0 is
ignored. A unique address for Slave 0 would be 1100 0010 since
slave 1 requires a 0 in bit 1. A unique address for slave 1 would be
1100 0001 since a 1 in bit 0 will exclude slave 0. Both slaves can be
selected at the same time by an address which has bit 0 = 0 (for
slave 0) and bit 1 = 0 (for slave 1). Thus, both could be addressed
with 1100 0000.
In a more complex system the following could be used to select
slaves 1 and 2 while excluding slave 0:
Slave 0
Slave 1
Slave 2
In the above example the differentiation among the 3 slaves is in the
lower 3 address bits. Slave 0 requires that bit 0 = 0 and it can be
it can be uniquely addressed by 1110 and 0101. Slave 2 requires
that bit 2 = 0 and its unique address is 1110 0011. To select Slaves 0
00H
01H
34H
24H
14H
02H
03H
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
=
=
=
=
=
T2CON
TMOD
EXTERNAL CONTROL (Note 2)
EXTERNAL CONTROL (Note 2)
1100 0000
1111 1101
1100 00X0
1100 0000
1111 1110
1100 000X
1100 0000
1111 1001
1100 0XX0
1110 0000
1111 1010
1110 0X0X
1110 0000
1111 1100
1110 00XX
80C31/80C32
0AH
0BH
08H
09H
36H
26H
16H
Product specification