ISP1161A1BMUM STEricsson, ISP1161A1BMUM Datasheet - Page 93

no-image

ISP1161A1BMUM

Manufacturer Part Number
ISP1161A1BMUM
Description
Manufacturer
STEricsson
Datasheet

Specifications of ISP1161A1BMUM

Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1161A1BMUM
Manufacturer:
LUMEX
Quantity:
12 000
Part Number:
ISP1161A1BMUM
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Philips Semiconductors
Table 75:
[1]
[2]
[3]
[4]
[5]
[6]
9397 750 13961
Product data
Name
Acknowledge Setup
General commands
Read Control OUT Error
Code
Read Control IN Error Code
Read Endpoint n Error Code
(n = 1 to 14)
Unlock Device
Write/Read Scratch register
Read Frame Number
Read Chip ID
Read Interrupt register
With N representing the number of bytes, the number of words for 16-bit bus width is: (N + 1)/2.
Validating an OUT endpoint buffer causes unpredictable behavior of the ISP1161A1’s DC.
Clearing an IN endpoint buffer causes unpredictable behavior of the ISP1161A1’s DC.
Reads a copy of the Status register: executing this command does not clear any status bits or interrupt bits.
When accessing an 8-bit register in 16-bit mode, the upper byte is invalid.
During isochronous transfer in 16-bit mode, because N
DC command and register summary
13.1.1 DcEndpointConfiguration register (R/W: 30H–3FH/20H–2FH)
13.1 Initialization commands
Initialization commands are used during the enumeration process of the USB
network. These commands are used to configure and enable the embedded
endpoints. They also serve to set the USB assigned address of the ISP1161A1’s DC
and to perform a device reset.
This command is used to access the Endpoint Configuration register (ECR) of the
target endpoint. It defines the endpoint type (isochronous or bulk/interrupt), direction
(OUT/IN), FIFO size and buffering scheme. It also enables the endpoint FIFO. The
register bit allocation is shown in
The allocation of FIFO memory only takes place after all 16 endpoints have been
configured in sequence (from endpoint 0 OUT to endpoint 14). Although the control
endpoints have fixed configurations, they must be included in the initialization
sequence and be configured with their default values (see
allocation starts when endpoint 14 has been configured.
Remark: If any change is made to an endpoint configuration which affects the
allocated memory (size, enable/disable), the FIFO memory contents of all endpoints
becomes invalid. Therefore, all valid data must be removed from enabled endpoints
before changing the configuration.
Code (Hex): 20 to 2F — write (control OUT, control IN, endpoint 1 to 14)
Code (Hex): 30 to 3F — read (control OUT, control IN, endpoint 1 to 14)
Destination
Endpoint 0 IN and OUT
DcErrorCode register
endpoint 0 OUT
DcErrorCode register
endpoint 0 IN
DcErrorCode register
endpoint 1 to 14
all registers with write
access
DcScratch register
DcFrameNumber register
DcChipID register
DcInterrupt register
Rev. 03 — 23 December 2004
…continued
1023, the firmware must take care of the upper byte.
Code
(Hex)
F4
A0
A1
A2 to AF
B0
B2/B3
B4
B5
C0
Table
USB single-chip host and device controller
Transaction
none
read 1 word
read 1 word
read 1 word
write 1 word
write/read 1 word
read 1 word
read 1 word
read 2 words
76. A bus reset will disable all endpoints.
[1]
[5]
[5]
[5]
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
Reference
Section 13.2.7 on page 103
Section 13.3.1 on page 103
Section 13.3.2 on page 104
Section 13.3.3 on page 105
Section 13.3.4 on page 105
Section 13.3.5 on page 106
Section 13.3.6 on page 107
Table
ISP1161A1
66). Automatic FIFO
92 of 136

Related parts for ISP1161A1BMUM