AD5175BRMZ-10 Analog Devices Inc, AD5175BRMZ-10 Datasheet - Page 17

IC DGTL POT 1024POS 10K 10MSOP

AD5175BRMZ-10

Manufacturer Part Number
AD5175BRMZ-10
Description
IC DGTL POT 1024POS 10K 10MSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5175BRMZ-10

Taps
1024
Resistance (ohms)
10K
Number Of Circuits
1
Temperature Coefficient
35 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V, ±2.5 V ~ 2.75 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Resistance In Ohms
10K
End To End Resistance
10kohm
Resistance Tolerance
-15% To +15%
No. Of Steps
1024
Supply Voltage Range
2.7V To 5.5V, ± 2.7V
Control Interface
I2C, Serial
No. Of Pots
Single
Memory
RoHS Compliant
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5175BRMZ-10
Manufacturer:
VISHAY
Quantity:
5 015
Part Number:
AD5175BRMZ-10
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5175BRMZ-10-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Bit Name
C0
C1
C2
Table 8. Write and Read to RDAC and 50-TP Memory
DIN
0x1C03
0x0500
0x0800
0x0C00
0x1800
0x0000
0x1419
0x2000
0x0000
1
Table 9. Control Register Bit Map
DB9
0
Table 10. Control Register Description
1
Table 11. Memory Map
Command Number
5
1
X is don’t care.
Wiper position is frozen to the last value programmed in the 50-TP memory. Wiper freezes to midscale if 50-TP memory has not been previously programmed.
X is don’t care.
SDO
0xXXXX
0x1C03
0x0500
0x100
0x0C00
0xXX19
0x0000
0x0100
0xXXXX
DB8
0
1
Action
Enable update of wiper position and 50-TP memory contents through digital interface.
Write 0x100 to the RDAC register, wiper moves to ¼ full-scale position.
Prepare data read from RDAC register.
Stores RDAC register content into 50-TP memory. 16-bit word appears out of SDO, where the last 10-bits contain the
contents of the RDAC Register 0x100.
Prepare data read of the last programmed 50-TP memory monitor location.
NOP Instruction 0 sends a 16-bit word out of SDO, where the six LSBs (that is, the last 6 bits) contain the binary address
of the last programmed 50-TP memory location, for example, 0x19 (see Table 11).
Prepares data read from Memory Location 0x19.
Prepare data read from the control register. Sends a 16-bit word out of SDO, where the last 10-bits contain the contents
of Memory Location 0x19.
NOP Instruction 0 sends a 16-bit word out of SDO, where the last four bits contain the contents of the control register.
If Bit C2 = 1, fuse program command successful.
Description
50-TP program enable
0 = 50-TP program disabled (default)
1 = enable device for 50-TP program
RDAC register write protect
0 = wiper position frozen to value in OTP memory (default)
1 = allow update of wiper position through a digital interface
50-TP memory program success bit
0 = fuse program command unsuccessful (default)
1 = fuse program command successful
D9
X
X
X
X
X
X
X
X
X
X
X
X
DB7
0
D8
X
X
X
X
X
X
X
X
X
X
X
X
D7
X
X
X
X
X
X
X
X
X
X
X
X
DB6
0
D6
0
0
0
0
0
0
0
0
0
0
0
0
Data Byte[DB9:DB0]
D5
0
0
0
0
0
0
0
0
1
1
1
1
DB5
0
D4
0
0
0
0
0
0
1
1
0
1
1
1
Rev. A | Page 17 of 20
D3
0
0
0
0
0
1
0
1
1
0
1
1
1
DB4
0
D2
0
0
0
0
1
0
1
1
0
0
0
0
D1
0
0
1
1
0
1
0
1
0
1
0
1
1
DB3
C2
D0
0
1
0
1
0
0
0
0
0
0
1
0
Register Contents
Reserved
1
2
3
4
10
20
30
40
50
MSB resistance tolerance (0x39)
LSB resistance tolerance (0x3A)
st
nd
rd
th
th
th
th
th
th
programmed wiper location (0x01)
programmed wiper location (0x03)
programmed wiper location (0x04)
programmed wiper location (0x02)
programmed wiper location (0xA)
programmed wiper location (0x14)
programmed wiper location (0x1E)
programmed wiper location (0x28)
programmed wiper location (0x32)
DB2
0
DB1
C1
AD5175
DB0
C0

Related parts for AD5175BRMZ-10