X9409WV24-2.7T1 Intersil, X9409WV24-2.7T1 Datasheet - Page 11

IC XDCP QUAD 64-TAP 10K 24-TSSOP

X9409WV24-2.7T1

Manufacturer Part Number
X9409WV24-2.7T1
Description
IC XDCP QUAD 64-TAP 10K 24-TSSOP
Manufacturer
Intersil
Series
XDCP™r
Datasheet

Specifications of X9409WV24-2.7T1

Taps
64
Resistance (ohms)
10K
Number Of Circuits
4
Temperature Coefficient
300 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Resistance In Ohms
10K
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
ABSOLUTE MAXIMUM RATINGS
Temperature under bias .................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Voltage on SDA, SCL or any address
Δ V = |V
Lead temperature (soldering, 10s) .................. +300°C
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Notes: (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as
RECOMMENDED OPERATING CONDITIONS
C
input with respect to V
Symbol
H
V
/C
TERM
Commercial
R
I
I
AL
W
Industrial
W
L
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potenti-
(3) MI = RTOT/63 or (V
Temp
/C
H
a potentiometer.
ometer. It is a measure of the error in step size.
W
- V
L
End to end resistance tolerance
Power rating
Wiper current
Wiper resistance
Voltage on any V
Noise
Resolution
Absolute linearity
Relative linearity
Temperature coefficient of R
Ratiometric temp. coefficient
Potentiometer capacitances
R
| ........................................................ 5V
H
, R
L
, R
W
SS
(4)
H
Parameter
-40°C
11
leakage current
Min.
......................... -1V to +7V
0°C
- V
L
)/63, single pot
(2)
H
(1)
/R
H
or V
L
/R
TOTAL
L
+70
+85
Max.
pin
° C
° C
Min.
V
-0.2
-3
-1
SS
X9409
10/10/25
±300
Typ.
-120
1.6
0.1
50
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification)
is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
X9409-2.7
Device
Limits
Max.
V
+0.2
±20
150
15
+3
+1
20
10
CC
ppm/
ppm/
MI
MI
Unit
dBV
mW
mA
pF
µA
%
%
Supply Voltage (V
Ω
V
(3)
(3)
° C
° C
I
V
Ref: 1kHz
V
V
See Macro Model
V
in stand-by mode.
25°C, each pot @5V, 2.5K
W
SS
w(n)(actual)
w(n + 1)
IN
2.7V to 5.5V
= ± 3mA, V
= V
= 0V
Test Conditions
SS
- [V
to V
CC
- V
w(n) + MI
CC
CC
) Limits
w(n)(expected)
= 3V to 5V
. Device is
October 12, 2006
]
FN8192.4

Related parts for X9409WV24-2.7T1