EP1S20F672I7 Altera, EP1S20F672I7 Datasheet - Page 90

IC STRATIX FPGA 20K LE 672-FBGA

EP1S20F672I7

Manufacturer Part Number
EP1S20F672I7
Description
IC STRATIX FPGA 20K LE 672-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S20F672I7

Number Of Logic Elements/cells
18460
Number Of Labs/clbs
1846
Total Ram Bits
1669248
Number Of I /o
426
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
672-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
18460
# I/os (max)
426
Frequency (max)
420.17MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
18460
Ram Bits
1669248
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
672
Package Type
FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S20F672I7
Manufacturer:
ALTERA
0
Part Number:
EP1S20F672I7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP1S20F672I7B
Manufacturer:
ALTERA
0
Part Number:
EP1S20F672I7N
Manufacturer:
ALTERA20
Quantity:
212
Part Number:
EP1S20F672I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S20F672I7N
Manufacturer:
ALTERA
0
Part Number:
EP1S20F672I7N
0
PLLs & Clock Networks
2–76
Stratix Device Handbook, Volume 1
Figure 2–43. Regional Clocks
Fast Regional Clock Network
In EP1S25, EP1S20, and EP1S10 devices, there are two fast regional clock
networks, FCLK[1..0], within each quadrant, fed by input pins that can
connect to fast regional clock networks (see
larger devices, there are two fast regional clock networks within each
half-quadrant (see
clock networks. All devices have eight FCLK pins to drive fast regional
clock networks. Any I/O pin can drive a clock or control signal onto any
fast regional clock network with the addition of a delay. This signal is
driven via the I/O interconnect. The fast regional clock networks can also
be driven from internal logic elements.
RCLK[1..0]
RCLK[4..5]
CLK[3..0]
Figure
2–45). Dual-purpose FCLK pins drive the fast
RCLK[6..7]
RCLK[2..3]
CLK[7..4]
RCLK[12..13]
RCLK[11..10]
CLK[15..12]
Figure
Regional Clocks Only Drive a Device
Quadrant from Specified CLK Pins or
PLLs within that Quadrant
2–44). In EP1S30 and
Altera Corporation
CLK[11..8]
RCLK[14..15]
July 2005
RCLK[9..8]

Related parts for EP1S20F672I7