SAA-XC866-2FRA 5V BE Infineon Technologies, SAA-XC866-2FRA 5V BE Datasheet - Page 63

no-image

SAA-XC866-2FRA 5V BE

Manufacturer Part Number
SAA-XC866-2FRA 5V BE
Description
IC MCU 8BIT FLASH PG-TSSOP-38
Manufacturer
Infineon Technologies
Series
XC8xxr
Datasheet

Specifications of SAA-XC866-2FRA 5V BE

Core Processor
XC800
Core Size
8-Bit
Speed
86MHz
Connectivity
SSI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
27
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2.3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 140°C
Package / Case
38-TFSOP (0.173", 4.40mm Width)
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With
MCBXC866 - BOARD EVAL FOR INFINEON XC86X
Other names
AX8662FRABEXT
SAA-XC866-2FRA BE
SAA-XC866-2FRA5VBEINTR
SAA-XC866-2FRABEINTR
SAA-XC866-2FRABEINTR
SP000281789
The clock system provides three ways to generate the system clock:
PLL Base Mode
The system clock is derived from the VCO base (free running) frequency clock divided
by the K factor.
Prescaler Mode (VCO Bypass Operation)
In VCO bypass operation, the system clock is derived from the oscillator clock, divided
by the P and K factors.
PLL Mode
The system clock is derived from the oscillator clock, multiplied by the N factor, and
divided by the P and K factors. Both VCO bypass and PLL bypass must be inactive for
this PLL mode. The PLL mode is used during normal system operation.
Table 20
selection.
Table 20
OSCDISC
0
0
1
1
Note: When oscillator clock is disconnected from PLL, the clock mode is PLL Base mode
System Frequency Selection
For the SAA-XC866, the values of P and K are fixed to “1” and “2”, respectively. In order
to obtain the required system frequency, f
for different oscillator inputs.
obtained for the different oscillator sources.
Data Sheet
regardless of the setting of VCOBYP bit.
shows the settings of bits OSCDISC and VCOBYP for different clock mode
Clock Mode Selection
VCOBYP
0
1
0
1
Table 21
f
f
SYS
SYS
f
SYS
=
=
=
provides examples on how f
f
f
VCObase
OSC
f
Clock Working Modes
PLL Mode
Prescaler Mode
PLL Base Mode
PLL Base Mode
sys
OSC
60
, the value of N can be selected by bit NDIV
×
×
-------------
P
-------------
P K
N
×
×
×
1
K
--- -
K
1
Functional Description
sys
= 80 MHz can be
SAA-XC866
V1.5, 2010-09