AD9891KBC Analog Devices Inc, AD9891KBC Datasheet - Page 27

no-image

AD9891KBC

Manufacturer Part Number
AD9891KBC
Description
IC CCD SIGNAL PROC/GEN 64-CSPBGA
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 10-Bitr
Datasheet

Specifications of AD9891KBC

Rohs Status
RoHS non-compliant
Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Mounting Type
Surface Mount
Package / Case
64-CSPBGA
Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Operating Supply Voltage (min)
2.7/3V
Resolution
10b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-20C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
64
Package Type
CSPBGA
Number Of Channels
1
Current - Supply
-
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9891KBC
Manufacturer:
AD
Quantity:
55
Part Number:
AD9891KBC
Manufacturer:
ADI
Quantity:
329
SUBCK Suppression
Normally, the SUBCKs will begin to pulse on the line following
the sensor gate line (VSG). With some CCDs, the SUBCKs
need to be suppressed for one or more lines following the VSG
line. The SUBCKSUPPRESS Register allows for the suppression
the SUBCK pulses for up to 63 lines following the VSG line.
Readout After Exposure
A write to the EXPOSURE Register will designate the number
fields in the exposure time (t
the readout of the CCD data occurs. During readout, the
SUBCK output may need to be further suppressed until the
readout is completed. The READOUT Register specifies the
number of additional fields after the exposure to continue the
suppression of SUBCK. READOUT can be programmed for
zero to seven additional fields and should be preprogrammed at
start-up, not at the same time as the exposure write. A typical
interlaced CCD frame readout mode will generally require two
additional fields of SUBCK suppression (READOUT = 2).
Note that a write to the EXPOSURE Register acts as a trigger
for readout after the exposure is completed. If no write to the
EXPOSURE Register occurs, than the READOUT Register will
have no effect. See Figure 35 for an example of triggering the
exposure and subsequent readout.
Register
SUBCKPOL*
SUBCK1TOG1*
SUBCK1TOG2*
SUBCK2TOG1*
SUBCK2TOG2*
SUBCKNUM*
SUBCKSUPPRESS*
EXPOSURE
VDHDOFF
READOUT
*Register is not VD/HD updated but is updated at the start of line after sensor gate line.
REV. A
SUBCK
NOTES
1. SUBCK MAY BE SUPPRESSED FOR MULTIPLE FIELDS BY PROGRAMMING THE EXPOSURE REGISTER GREATER THAN ZERO.
2. ABOVE EXAMPLE USES EXPOSURE = 1.
3. VD/HD OUTPUTS MAY ALSO BE SUPPRESSED USING THE VDHDOFF REGISTER = 1.
VSG1–
VSG8
VD
EXP
Length
1b
12b
12b
12b
12b
12b
6b
12b
1b
3b
) from 0 to 4095. After the exposure,
Figure 32. Low Speed Shutter Mode Using EXPOSURE Register
Table XIV. Electronic Shutter Mode Register Parameters
Range
HIGH/LOW
0–4095 Pixel Location
0–4095 Pixel Location
0–4095 Pixel Location
0–4095 Pixel Location
0–4095 # of Pulses
0–63 # of Pulses
0–4095 # of Fields
ON/OFF
0–7 # of Fields
–27–
VSUB Control
The CCD readout bias (VSUB) can be programmed to accom-
modate different CCDs. Figure 35 shows two different modes
that are available. In Mode 0, VSUB goes active during the
field of the last SUBCK when the exposure begins. The
on-position (rising edge in Figure 35) is programmable to any
line within the field. VSUB will remain active until the end of
the image readout. In Mode 1, the VSUB is not activated
until the start of the readout.
MSHUT and STROBE Control
MSHUT and STROBE operation is shown in Figures 33, 34,
and 35. Table XV shows the registers parameters for control-
ling the MSHUT and STROBE outputs. The MSHUT output
is switched on with the MSHUTON Registers, and it will
remain on until the location specified in the MSHUTOFF
Registers. The location of MSHUTOFF is fully programmable to
anywhere within the exposure period, using the FD (field), LN
(line), and PX (pixel) Registers. The STROBE pulse is defined
by the ON and OFF positions. STROBON_FD is the field in
which the STROBE is turned on, measured from the field con-
taining the last SUBCK before exposure begins. The
STROBON_ LN and STROBON_PX Registers give the line
and pixel positions with respect to STROBON_FD. The
STROBE off position is programmable to any field, line, and
pixel location with respect to the field of the last SUBCK.
Description
SUBCK Start Polarity for SUBCK1 and SUBCK2
SUBCK First Toggle Position
SUBCK Second Toggle Position
Second SUBCK First Toggle Position (for High Precision Mode)
Second SUBCK Second Toggle Position (for High Precision Mode)
Total Number of SUBCKs per Field (at 1 Pulse per Line)
Number of SUBCK’s to Suppress after VSG Line
Number of Fields to Suppress to SUBCK and VSG;
Triggers Readout to Occur after t
Disable VD/HD Output during Exposure (1 = On, 0 = Off)
Number of Fields to Suppress SUBCK after Exposure (for Readout)
t
EXP
EXP
AD9891/AD9895