M28W320FCT70ZB6E Micron Technology Inc, M28W320FCT70ZB6E Datasheet - Page 21

no-image

M28W320FCT70ZB6E

Manufacturer Part Number
M28W320FCT70ZB6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M28W320FCT70ZB6E

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
21b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TFBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
2M
Supply Current
18mA
Mounting
Surface Mount
Pin Count
47
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W320FCT70ZB6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M28W320FCT70ZB6E
Manufacturer:
ST
0
Part Number:
M28W320FCT70ZB6E
Manufacturer:
ST
Quantity:
20 000
4.13
4.14
4.15
Block Lock command
The Block Lock command is used to lock a block and prevent Program or Erase operations
from changing the data in it. All blocks are locked at power-up or reset.
Two Bus Write cycles are required to issue the Block Lock command.
1.
2.
The lock status can be monitored for each block using the Read Electronic Signature
command.
The Block Lock bits are volatile, once set they remain set until a hardware reset or power-
down/power-up. They are cleared by a Blocks Unlock command. Refer to the section, Block
Locking, for a detailed explanation.
Block Unlock command
The Block Unlock command is used to unlock a block, allowing the block to be programmed
or erased. Two Bus Write cycles are required to issue the Block Unlock command.
1.
2.
The lock status can be monitored for each block using the Read Electronic Signature
command.
Refer to the section, Block Locking, for a detailed explanation.
Block Lock-Down command
A locked block cannot be Programmed or Erased, or have its protection status changed
when WP is low, V
locked blocks can be individually unlocked by the Block Unlock command.
Two Bus Write cycles are required to issue the Block Lock-Down command.
1.
2.
The lock status can be monitored for each block using the Read Electronic Signature
command. Locked-Down blocks revert to the locked (and not locked-down) state when the
device is reset on power-down.
Lock-Down command. Refer to the section, Block Locking, for a detailed explanation.
The first bus cycle sets up the Block Lock command.
The second Bus Write cycle latches the block address.
The first bus cycle sets up the Block Unlock command.
The second Bus Write cycle latches the block address.
The first bus cycle sets up the Block Lock command.
The second Bus Write cycle latches the block address.
Table 10
Table 10
IL
. When WP is high, V
shows the protection status after issuing a Block Lock command.
shows the protection status after issuing a Block Unlock command.
Table 10
shows the protection status after issuing a Block
IH,
the Lock-Down function is disabled and the
21/69