RC28F256P30B85 Micron Technology Inc, RC28F256P30B85 Datasheet - Page 38

no-image

RC28F256P30B85

Manufacturer Part Number
RC28F256P30B85
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of RC28F256P30B85

Cell Type
NOR
Density
256Mb
Access Time (max)
85/17ns
Interface Type
Parallel/Serial
Boot Type
Bottom
Address Bus
24b
Operating Supply Voltage (typ)
1.8V
Operating Temp Range
-40C to 85C
Package Type
EZBGA
Program/erase Volt (typ)
1.7 to 2/8.5 to 9.5V
Sync/async
Async/Sync
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
1.7V
Operating Supply Voltage (max)
2V
Word Size
16b
Number Of Words
16M
Supply Current
28mA
Mounting
Surface Mount
Pin Count
64
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RC28F256P30B85A
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
RC28F256P30B85D
Manufacturer:
Micron Technology Inc
Quantity:
10 000
10.1.4
Figure 12: Block Locking State Diagram
10.1.5
Note:
Datasheet
38
or Lock-Down Block produces a command sequence error and set Status Register bits SR[4]
and SR[5]. If a command sequence error occurs during an erase suspend, SR[4] and SR[5]
remains set, even after the erase operation is resumed. Unless the Status Register is cleared
using the Clear Status Register command before resuming the erase operation, possible erase
errors may be masked by the command sequence error.
A Lock Block Setup command followed by any command other than Lock Block, Unlock Block,
Power-Up/Reset
Notes:
Block Lock Status
The Read Device Identifier command is used to determine a block’s lock status (see
Section 12.0, “Power and Reset Specifications” on page
the addressed block’s lock status; DQ0 is the addressed block’s lock bit, while DQ1 is
the addressed block’s lock-down bit.
Block Locking During Suspend
Block lock and unlock changes can be performed during an erase suspend. To change
block locking during an erase operation, first issue the Erase Suspend command.
Monitor the Status Register until SR[7] and SR[6] are set, indicating the device is
suspended and ready to accept another command.
Next, write the desired lock command sequence to a block, which changes the lock
state of that block. After completing block lock or unlock operations, resume the erase
operation using the Erase Resume command.
1. [a,b,c] represents [WP#, DQ1, DQ0]. X = Don’t Care.
2. DQ1 indicates Block Lock-Down status. DQ1 = ‘0’, Lock-Down has not been issued
3. DQ0 indicates block lock status. DQ0 = ‘0’, block is unlocked. DQ0 = ‘1’, block is
4. Locked-down = Hardware + Software locked.
5. [011] states should be tracked by system software to determine difference between
to this block. DQ1 = ‘1’, Lock-Down has been issued to this block.
locked.
Hardware Locked and Locked-Down states.
Unlocked
Locked
[X01]
[X00]
Software Block Lock (0x60/0x01) or Software Block Unlock (0x60/0xD0)
Software Block Lock-Down (0x60/0x2F)
W P# hardware control
Software
Locked-
Down
Locked
[111]
[011]
4,5
WP# Hardware Control
50). Data bits DQ[1:0] display
Hardware
Unlocked
Locked
[011]
[110]
5
August 2008
306666-12